Siemens 3RW5244-2TC04 SIRIUS Soft Starter, 100 A, 200-480 V

MPN3RW5244-2TC04
Active

Siemens SIRIUS 3RW5244-2TC04 hybrid soft starter, 100 A minimum, 200-480 V, Class 10A/10E/20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing, 210 x 393 x 203 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5244-2TC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5244-2TC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 188 W

Control & Connection

3RW5244-2TC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5244-2TC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5244-2TC04 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5244-2TC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5244-2TC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5244-2TC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5244-2TC04 is a SIRIUS soft starter rated for a minimum operating current of 100 A across a 200-480 V supply. That 100 A floor is the smallest settable Ie — it governs the motor FLA you can protect, not the full-load current the device can handle. The trip class defaults to CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E curves, so it matches standard induction-motor starting profiles without nuisance tripping on normal acceleration. Fieldbus support is comprehensive: PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET are all on board. PROFIenergy is available when paired with the PROFINET communication module. This makes the 3RW5244-2TC04 a single-stock-keeping unit for plants running mixed network topologies — no need to swap hardware for different fieldbus segments.

Frequently asked questions

Is the 3RW5244-2TC04 compatible with PROFIBUS and Modbus?

Yes, the 3RW5244-2TC04 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET. PROFIenergy is available when used with the PROFINET communication module.

What is the difference between 3RW5244 and 3RW5245?

The 3RW5244-2TC04 is rated for a minimum operating current of 100 A, while the 3RW5245 family steps up to a higher current class. The exact rating difference depends on the specific variant; for a 3RW5245, check its datasheet for the minimum settable Ie.

MPN