Skip to main content
Siemens 3RW5244-6TC04 — Soft Starters

Siemens 3RW5244-6TC04 SIRIUS Soft Starter, 100 A, 200-480 V

MPN3RW5244-6TC04
Active

Siemens SIRIUS 3RW5244-6TC04 soft starter, minimum 100 A, rated 200-480 V, Trip Class 10A/10E/20E, screw fixing, 393 x 210 x 203 mm, multi-protocol communications.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5244-6TC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5244-6TC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 188 W

Control & Connection

3RW5244-6TC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5244-6TC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5244-6TC04 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5244-6TC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5244-6TC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5244-6TC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Soft starter for motor starting duty

The Siemens SIRIUS 3RW5244-6TC04 is a hybrid switching device — a soft starter — sized for motor starting applications up to 100 A minimum load (relative to smallest settable Ie) on a 200 to 480 V supply. Its Trip Class 10A default, with selectable 10E and 20E curves per IEC 60947-4-2, means it handles standard and heavy-start loads: Class 10A clears within 10 seconds at locked-rotor current, while Class 20E extends that window for high-inertia loads like centrifuges or crushers. The 100 A minimum rating governs the smallest motor it can soft-start; for smaller motors, a lower-rated unit would be needed.

Multi-protocol fieldbus and motor control features

This soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — no separate communication module required for most networks. PROFIenergy is supported in conjunction with the PROFINET standard communication module. The unit includes soft torque for gentle starts on conveyors or pumps, and a pump ramp-down function to reduce water hammer on pump stop. Auto-reset and remote reset (by cycling the 24 V DC control supply) are built in. An error logbook is available only with special accessories.

Mounting, environment, and approvals

Mounting is screw fixing on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Dimensions: 393 mm height, 210 mm width, 203 mm depth. Pollution degree 3 per IEC 60947-4-2. Shock resistance is 15 g / 11 ms. The control supply is 24 V DC.

Frequently asked questions

Is the 3RW5244-6TC04 soft starter active or obsolete?

Buyers need to know lifecycle status for long-term system planning and support availability.

What is the price of 3RW5244-6TC04?

Pricing directly impacts procurement decisions and budget planning.

Where can I buy 3RW5244-6TC04 in stock?

Immediate availability is critical to avoid production downtime.

What is the datasheet for 3RW5244-6TC04?

Engineers need detailed specifications for design validation and system integration.

How to replace 3RW5244-6TC04 with an equivalent?

Maintenance techs and buyers need drop-in replacements for failed units or alternate sourcing.

What are the dimensions of 3RW5244-6TC04?

Physical fit in panels is essential for installation without rework.

MPN
3RW5244-6TC04