Skip to main content
Siemens 3RW5244-6TC15 — Soft Starters

Siemens 3RW5244-6TC15 SIRIUS Soft Starter, 100 A, 200-600 V

MPN3RW5244-6TC15
Active

Siemens SIRIUS 3RW5244-6TC15 hybrid soft starter, 100 A minimum, 200-600 VAC, Trip Class 10A/10E/20E, with multi-protocol fieldbus (PROFINET, PROFIBUS, Modbus TCP/RTU, EtherNet/IP), screw fixing, 393 x 210 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5244-6TC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5244-6TC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 188 W

Control & Connection

3RW5244-6TC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5244-6TC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5244-6TC15 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5244-6TC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5244-6TC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5244-6TC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5244-6TC15 is a SIRIUS hybrid soft starter rated for a minimum motor current of 100 A at line voltages from 200 to 600 VAC (50/60 Hz). The Trip Class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2 — 10A is the standard for standard-start pumps and fans where the motor reaches full speed in under 10 seconds; 20E buys you extra thermal headroom for high-inertia loads like centrifuges or large conveyors that take longer to accelerate. The 100 A minimum rating means this unit is sized for motor FLA at or above that figure — it does not scale down to a 75 A motor without risking nuisance tripping on the minimum-load threshold of 15% of the smallest settable Ie. The 3RW5244-6TC15 carries a full suite of fieldbus interfaces onboard: PROFINET standard, PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. That means it drops into a greenfield PROFINET line or a legacy Modbus RTU multidrop without an external gateway. PROFIenergy is supported in conjunction with the PROFINET communication module, which lets the drive park the motor during idle periods in a production cell and save standby energy.

Mounting is screw-fixing only — no DIN-rail clip on this frame size. The unit measures 393 mm high by 210 mm wide by 203 mm deep, so plan for a backplate area roughly 400 x 220 mm with clearance: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. The mounting surface must be vertical; the unit can be rotated ±90° or tilted ±22.5° front-to-back. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting starting at 12 g / 11 ms — the contactor section inside the hybrid switch can bounce under sustained vibration above that threshold, so mount on a panel that does not transmit heavy mechanical shock from adjacent contactors or breakers.

Frequently asked questions

Where can I buy the 3RW5244-6TC15 soft starter?

The 3RW5244-6TC15 is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability — stock levels and lead time are confirmed at quote time.

What is the price of 3RW5244-6TC15?

Pricing for the 3RW5244-6TC15 is confirmed at quote time against an RFQ. Because market pricing fluctuates with volume and channel, the figure is provided on request — no published list price is carried here.

Can 3RW5244-6TC15 be reset automatically?

Yes, the 3RW5244-6TC15 supports auto-reset. Remote reset is also possible by cycling the control supply voltage off and back on.

What fieldbus protocols does the 3RW5244-6TC15 support?

The 3RW5244-6TC15 supports PROFINET standard, PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. PROFIenergy is available when used with the PROFINET communication module.

MPN
3RW5244-6TC15