Siemens 3RW5245-2AC14 — Soft Starters

Siemens 3RW5245-2AC14 SIRIUS Soft Starter, 135 A, 200-480 V

MPN3RW5245-2AC14
Active

Siemens SIRIUS 3RW5245-2AC14 soft starter, 135 A minimum, 200-480 V rated, trip class 10A/10E/20E, with PROFIBUS, Modbus TCP, EtherNet/IP, and PROFINET communications.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5245-2AC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5245-2AC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)160 kW
Rated motor power at 230 V (40 °C)90 kW
Rated operational current at 40 °C546 A
Rated operational current at 50 °C483 A
Rated operational current at 60 °C442 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 471 W

Control & Connection

3RW5245-2AC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5245-2AC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5245-2AC14 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5245-2AC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5245-2AC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5245-2AC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and motor protection

The 3RW5245-2AC14 is a SIRIUS soft starter with a default trip class of CLASS 10A per IEC 60947-4-2, with selectable 10E or 20E for heavier starting duty. Minimum settable current is 135 A, so this unit is sized for motor FLA down to that floor. Below 135 A you need a smaller frame in the 3RW52 family.

Fieldbus and control wiring

Communications stack is broad: PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET with PROFIenergy support — all onboard or via the standard communication module. That means it drops into most plant networks without a gateway. Analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameterization. The remote reset is done by cycling the control supply voltage off then on — no separate reset terminal to wire.

Screw-fixing mount on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, 0 mm backward. That 100 mm top clearance is the one that catches people — skimp on it and you lose airflow for the heat sink. Shock rated at 15 g / 11 ms. Dimensions: 393 mm high, 210 mm wide, 203 mm deep — verify panel door clearance before cutting the hole.

Frequently asked questions

What is the trip class of the 3RW5245-2AC14?

Default trip class is CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E or CLASS 20E for higher-inertia loads.

What communication protocols does the 3RW5245-2AC14 support?

It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET with PROFIenergy.

Where can I buy the 3RW5245-2AC14?

This part is sourced to order; availability and pricing are confirmed at quote time.

MPN
3RW5245-2AC14