Skip to main content
Siemens 3RW5245-2TC05

Siemens 3RW5245-2TC05 SIRIUS Soft Starter, 135 A, 200-600 V

MPN 3RW5245-2TC05
Active

Siemens SIRIUS 3RW5245-2TC05 soft starter, 135 A minimum operating current, 200-600 V AC, Trip Class 10A/10E/20E, screw fixing, 203 x 210 x 393 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5245-2TC05 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width210 mm
Height393 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

The 3RW5245-2TC05 is a SIRIUS soft starter rated for a minimum operating current of 135 A at a supply voltage of 200 to 600 V AC. That 135 A floor is the smallest settable Ie — the part cannot be dialed down below that, so it fits motor loads sized from 135 A upward. Trip Class is selectable: default CLASS 10A, with 10E and 20E options per IEC 60947-4-2. CLASS 10A trips within 10 seconds at 7.2× rated current, matching standard induction-motor starts; 20E gives a longer ramp window for high-inertia loads like centrifuges or fans. Fieldbus options are extensive: PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET with PROFIenergy support. That means the starter integrates into nearly any control network without a separate gateway — a single part covers both the power switching and the communication layer. Mounting is screw-fixing on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Clearances required: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, 0 mm backward. That 100 mm upward gap is the main constraint in a shallow cabinet — plan the gland plate or busbar clearance accordingly.

Integration notes

The starter supports soft torque and pump ramp down — both useful for reducing mechanical stress on the load and avoiding pressure surges in pumping applications. Remote reset is handled by cycling the 24 V control supply off and on, which simplifies remote restart without a dedicated reset signal. Shock resistance is rated at 15 g for 11 ms, with potential contact lifting above 12 g. That is robust for most industrial environments but worth noting if the starter is mounted on a vibrating machine base — derating the shock spec may be needed. An error logbook is available only with special accessories — not built-in. If detailed fault logging is required, factor in the accessory cost and mounting space at the design stage.

MPN