Siemens 3RW5245-6AC15 — Soft Starters

Siemens 3RW5245-6AC15 SIRIUS Soft Starter, 135 A, 200-600 V

MPN3RW5245-6AC15
Active

Siemens SIRIUS 3RW5245-6AC15 soft starter, 135 A minimum, 200-600 V rated voltage, Class 10A/10E/20E, PROFINET/Modbus/EtherNet/IP, UL/CSA/CE, screw fixing, 203 mm depth.

StockContact for availability
Lead time1-2 Weeks wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5245-6AC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5245-6AC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)160 kW
Rated motor power at 230 V (40 °C)90 kW
Rated operational current at 40 °C546 A
Rated operational current at 50 °C483 A
Rated operational current at 60 °C442 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 471 W

Control & Connection

3RW5245-6AC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5245-6AC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5245-6AC15 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5245-6AC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5245-6AC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5245-6AC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The 3RW5245-6AC15 is a SIRIUS hybrid switching device rated for a minimum motor current of 135 A at a rated voltage of 200 to 600 V. This is the floor for the smallest settable Ie — you size the soft starter to the motor FLA, not the other way around, and the 135 A minimum means it won't reliably start a motor drawing less than about 20 A (15 % of 135 A). Trip class is selectable: CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. Class 10A clears an overload in 10 seconds at 7.2× Ie — standard for most pump and fan starts. Class 20E extends the thermal budget to 20 seconds, useful for high-inertia loads like centrifuges where the start takes longer. Soft torque and pump ramp down are built in, so the acceleration and deceleration profiles can be tuned to avoid water hammer in pumping stations or mechanical shock on conveyor belts.

Fieldbus and control integration

This soft starter ships with PROFINET standard onboard, plus Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS. That means it drops into most common industrial networks without an extra gateway — one cable for control and parameterization. PROFIenergy is supported when used with the PROFINET communication module, allowing energy management during idle phases — relevant for production lines with scheduled stops. The analog output is configurable as 4-20 mA (default) or 0-10 V, parameterizable via the High Feature HMI (not included). This feeds motor current or load data to a PLC or SCADA without a separate transducer.

Mounting and clearance — what fits in the panel

Dimensions are 203 mm depth, 210 mm width, 393 mm height. Mounting is screw fixing to a vertical surface; the unit can be rotated ±90° and tilted ±22.5° front-to-back, so it fits in tight enclosures as long as the orientation doesn't block the cooling airflow. Minimum clearance around the unit: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. The 100 mm top clearance is the critical one — that's where hot air rises; skimping here derates the unit above 40 °C ambient.

Approvals include UL, CSA, and CE marking — covers North American and European installations without separate certification paperwork. The shock resistance is 15 g / 11 ms, which is typical for industrial panel-mounted gear — fine for most conveyor and pump applications.

Frequently asked questions

What fieldbus protocols does 3RW5245-6AC15 support?

It supports PROFINET standard, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS onboard. PROFIenergy is available with the PROFINET communication module.

What is the minimum motor current for 3RW5245-6AC15?

The minimum settable motor current is 135 A. The minimum load is 15 % of that, so about 20 A is the practical floor for reliable starting.

What approvals does 3RW5245-6AC15 carry?

It carries UL approval, CSA approval, and CE marking — suitable for North American and European installations.