Skip to main content
Siemens 3RW5246-2TC05 — Soft Starters

Siemens 3RW5246-2TC05 SIRIUS Soft Starter, 160 A, 200-600 V

MPN3RW5246-2TC05
Active

Siemens SIRIUS 3RW5246-2TC05 hybrid switching device, soft starter, 160 A minimum, 200-600 V, Class 10A/10E/20E, PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, PROFINET, screw fixing, 203 mm depth, 210 mm width, 393 mm height.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5246-2TC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5246-2TC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 kW
Rated motor power at 230 V (40 °C)110 kW
Rated operational current at 40 °C641 A
Rated operational current at 50 °C568 A
Rated operational current at 60 °C519 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 706 W

Control & Connection

3RW5246-2TC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5246-2TC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5246-2TC05 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5246-2TC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5246-2TC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5246-2TC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

SIRIUS 3RW5246-2TC05 soft starter — current production, multi-protocol fieldbus

Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, giving the commissioning engineer flexibility to match the motor thermal model and starting duty cycle without swapping hardware.

Mounting, clearance, and environmental limits

Fastening method is screw fixing; the unit measures 203 mm deep by 210 mm wide by 393 mm high. Required clearances: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the side — these numbers govern the panel layout and must be respected for airflow and arc-flash containment. Mounting position allows a vertical mounting surface with +/-90° rotation and +/-22.5° tilt front-to-back, which simplifies installation in cabinets where the backplane is not perfectly plumb. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting is a concern. Pollution degree 3 per IEC 60947-4-2 confirms suitability for industrial environments with conductive dust or occasional condensation.

Approvals and compliance documentation

UL approval, CSA approval, and CE marking are all confirmed on this variant — the compliance package covers North American and European installations without additional agency review. The unit supports firmware updates in the field, and an error logbook is available when paired with the special accessory. Soft torque and pump ramp down are built-in features for reducing mechanical shock on conveyors or pump start/stop cycles. Remote reset is possible by cycling the 24 V control supply voltage; auto-reset is also selectable, which the field service tech can use to restart after a cleared fault without a panel visit.

Frequently asked questions

What is 3RW5246-2TC05's listed depth (203 mm) on this component line?

The depth is 203 mm, with a width of 210 mm and a height of 393 mm. These dimensions plus the specified clearances (100 mm up, 10 mm forward, 0 mm back, 75 mm down, 5 mm side) define the minimum panel footprint.

What compliance documentation does this brand provide for 3RW5246-2TC05 (RoHS, REACH, UL, IEC)?

UL approval, CSA approval, and CE marking are confirmed on this unit. It is designed to IEC 60947-4-2 for trip class and pollution degree. RoHS/REACH declarations are typically available from the manufacturer upon request; the distributor can supply the relevant certificates at quote time.

MPN