Skip to main content
Siemens 3RW5246-6TC04 — Soft Starters

Siemens 3RW5246-6TC04 SIRIUS Soft Starter, 160 A, 200-480 V

MPN3RW5246-6TC04
Active

Siemens SIRIUS 3RW5246-6TC04 soft starter, 160 A minimum, 200-480 VAC, Class 10A/10E/20E, with PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5246-6TC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5246-6TC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 kW
Rated motor power at 230 V (40 °C)110 kW
Rated operational current at 40 °C641 A
Rated operational current at 50 °C568 A
Rated operational current at 60 °C519 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 706 W

Control & Connection

3RW5246-6TC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5246-6TC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5246-6TC04 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5246-6TC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5246-6TC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5246-6TC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5246-6TC04 is a SIRIUS soft starter rated for a minimum motor current of 160 A across a 200-480 VAC supply — that 160 A floor is the smallest motor you can set it to protect, not a maximum. The trip class defaults to CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E curves, so it handles standard and heavy-start loads like conveyors or crushers without nuisance tripping. Control voltage is 24 VDC, which keeps the panel wiring consistent with modern PLC-based control schemes. The unit supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET out of the box, plus PROFIenergy for coordinated energy management when paired with a PROFINET communication module. That makes it a drop-in for Siemens or Rockwell environments without needing a separate gateway.

Screw-fixing mount on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward. The 393 x 210 x 203 mm (H x W x D) envelope fits standard 800 mm wide enclosures with room for side-mounted bypass contactors.

The CE marking covers the Low Voltage and EMC directives for industrial environments.

Frequently asked questions

What is the trip class of 3RW5246-6TC04?

The default trip class is CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E curves. Class 10A handles standard motor starts; 20E is for high-inertia loads like fans or centrifuges that need a longer acceleration ramp.

Is 3RW5246-6TC04 compatible with Modbus RTU?

Yes, Modbus RTU is supported natively — no external gateway needed. Also supports Modbus TCP, PROFIBUS, EtherNet/IP, and PROFINET.