Siemens 3RW5247-6TC05 SIRIUS Soft Starter, 200 A, 200-600 V

MPN3RW5247-6TC05
Active

Siemens SIRIUS 3RW5247-6TC05 soft starter, 200 A minimum rated current, 200-600 V, Class 10A/10E/20E per IEC 60947-4-2, PROFIBUS/Modbus RTU/TCP/EtherNet/IP/PROFINET, screw fixing, 203 x 210 x 393 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5247-6TC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5247-6TC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)250 kW
Rated motor power at 230 V (40 °C)132 kW
Rated operational current at 40 °C814 A
Rated operational current at 50 °C721 A
Rated operational current at 60 °C658 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)6 604 W

Control & Connection

3RW5247-6TC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5247-6TC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5247-6TC05 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5247-6TC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5247-6TC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5247-6TC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What the 200 A minimum rating means for your motor string

The 3RW5247-6TC05 is a SIRIUS hybrid switching device with a minimum settable operating current of 200 A across a voltage range of 200 to 600 V. This is the floor for the motor FLA you can connect — anything below 200 A and the starter cannot be adjusted down to protect the winding. Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2.

Fieldbus and control integration — which protocols are on board

Native support for PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard means this unit drops into most common industrial networks without an external gateway. PROFIenergy is available when paired with the PROFINET standard communication module. Remote reset is achieved by cycling the 24 V DC control supply voltage. The unit also supports auto-reset and firmware updates — useful for fleet-wide parameter changes without opening the panel.

Mounting clearances and panel fit

Screw fixing on a vertical mounting surface; the unit can be rotated ±90° or tilted ±22.5° front-to-back. Required free air space: 100 mm above, 10 mm in front, 75 mm below, 5 mm at the sides, and 0 mm behind. Overall dimensions are 203 mm deep, 210 mm wide, and 393 mm tall. The depth is the critical dimension for shallow enclosures — verify the back panel clearance against the 203 mm plus the 10 mm forward clearance.

Environmental limits and derating

Pollution degree 3 per IEC 60947-4-2 means it tolerates conductive dust and occasional condensation — typical for unheated pump houses or washdown areas. Shock resistance is 15 g / 11 ms, with potential contact lifting at 12 g / 11 ms. Service factor is 1 — no continuous overload margin beyond nameplate; size the motor FLA at or below the 200 A minimum.

Application-specific features for pump and soft-torque loads

Pump ramp down and soft torque are built in — pump ramp down gradually reduces torque during stop to prevent water hammer; soft torque reduces inrush on high-friction starts like conveyors with loaded belts. Minimum load is 15% of the smallest settable Ie. No analog output and no torque control — this is a voltage-ramp soft starter, not a closed-loop torque controller. Error logbook is available only with special accessories.

Compliance and approvals for global installs

CE marking, UL approval, and CSA approval are all confirmed. This covers installations under IEC, NEC, and Canadian Electrical Code jurisdictions — no additional agency review needed for most industrial sites.

Frequently asked questions

What compliance documentation does Siemens provide for the 3RW5247-6TC05?

CE marking, UL approval, and CSA approval are confirmed on the product record. These cover the essential regulatory declarations for IEC, UL, and CSA jurisdictions.

MPN
3RW5247-6TC05