Siemens 3RW5248-2AC04 SIRIUS Soft Starter, 240 A, 200-480 V

MPN3RW5248-2AC04
Active

Siemens SIRIUS 3RW5248-2AC04 soft starter, 240 A minimum rated current, 200-480 V AC, Class 10A/10E/20E, screw fixing, 393 x 210 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5248-2AC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5248-2AC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)315 kW
Rated motor power at 230 V (40 °C)160 kW
Rated operational current at 40 °C987 A
Rated operational current at 50 °C873 A
Rated operational current at 60 °C796 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)8 500 W

Control & Connection

3RW5248-2AC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5248-2AC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5248-2AC04 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight10.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5248-2AC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5248-2AC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5248-2AC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Form factor and mounting — panel fit for a 393 mm tall unit

The 3RW5248-2AC04 measures 393 mm high by 210 mm wide by 203 mm deep, with screw fixing as the fastening method. Mounting position allows vertical surface orientation with ±90° rotation and ±22.5° tilt forward/backward. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind.

Rated current and trip class — what the 240 A minimum means

The minimum rated operating current is 240 A, with a minimum load of 15 % relative to the smallest settable Ie. Trip class is configurable: default Class 10A, with options for 10E and 20E, all per IEC 60947-4-2. This means the soft starter can handle motor start profiles from standard (10A) to extended (20E) acceleration times, depending on the load inertia.

Voltage range and approvals — 200-480 V with UL/CSA/CE

Rated supply voltage is 200 to 480 V AC. The unit carries UL, CSA, and CE marking, covering installations in North American and European markets. Pollution degree 3 per IEC 60947-4-2 suits industrial environments with conductive dust or moisture.

Communication interfaces — PROFIBUS, PROFINET, Modbus, EtherNet/IP

Built-in communication options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard. PROFIenergy support is available with the PROFINET standard communication module. An analog output (4-20 mA default, parameterizable to 0-10 V with High Feature HMI) provides motor current feedback for monitoring.

Environmental and operating limits

Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting occurs. The unit supports auto-reset and remote reset by cycling the control supply voltage.