Skip to main content
Siemens 3RW5248-2TC04 — Soft Starters

Siemens 3RW5248-2TC04 Soft Starter, 240 A, 200-480 V, SIRIUS

MPN3RW5248-2TC04
Active

Siemens SIRIUS 3RW5248-2TC04 soft starter, 240 A minimum, 200-480 V, Class 10A/10E/20E, screw fixing, 393 x 210 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5248-2TC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5248-2TC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)315 kW
Rated motor power at 230 V (40 °C)160 kW
Rated operational current at 40 °C987 A
Rated operational current at 50 °C873 A
Rated operational current at 60 °C796 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)8 500 W

Control & Connection

3RW5248-2TC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5248-2TC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5248-2TC04 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight10.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5248-2TC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5248-2TC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5248-2TC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

240 A minimum, 200-480 V — the operating envelope

The 3RW5248-2TC04 is a SIRIUS hybrid switching device rated for a minimum operating current of 240 A across a 200-480 V supply range. That 240 A floor governs the smallest settable motor full-load current the unit can regulate — set the ramp below it and the internal current loop loses resolution, so the BOM motor FLA must land at or above that figure. Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. Stepping to 20E buys you double the thermal budget for high-inertia conveyors or crusher drums that take longer to spin up.

Mounting clearances and thermal derating

Screw-fixed mounting on a vertical surface, rotatable ±90° or tiltable ±22.5° front-to-back. The mandatory free-air clearances are 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, and zero backwards — stack that against the gland-plate and busbar layout before committing the panel layout. The 393 × 210 × 203 mm envelope (height × width × depth) sets the DIN-rail or backplate footprint. A 50 °C cabinet interior pulls the continuous current capability down — the exact curve is in the product documentation, but the rule of thumb is to budget 1-2% per degree above 40 °C for the SIRIUS 3RW52 family. Pollution degree 3 per IEC 60947-4-2 means the unit tolerates conductive dust and condensation typical of industrial enclosures without conformal coating.

Fieldbus selection and control features

The soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module needed for any of these five protocols. PROFIenergy is supported when used with the PROFINET standard communication module, letting the drive coordinate energy-saving pauses during production idle periods. Soft torque and pump ramp down are built in — the ramp-down profile reduces pressure surges on discharge lines during pump stop sequences. Auto-reset is available, and remote reset is achieved by cycling the 24 V control supply off and on. The unit logs errors to an internal logbook, though that requires the special accessory module.

Approvals and compliance documentation

CE marking, UL approval, and CSA approval are all confirmed on the nameplate — the unit carries acceptance for European low-voltage directive, North American NRTL listing, and Canadian standards. The pollution degree 3 rating and IEC 60947-4-2 trip-class certification cover the functional safety and environmental withstand for fixed-installation industrial motor control. Shock resistance is specified at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms — relevant for installation on vibrating skids or near reciprocating compressors where the panel sees repetitive impulse loads.

Frequently asked questions

What are the key fieldbus options on the 3RW5248-2TC04?

The soft starter includes PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET onboard. No separate communication module is needed for these protocols.

MPN
3RW5248-2TC04