Siemens 3RW5513-1HF04 — Soft Starters

Siemens 3RW5513-1HF04 Soft Starter, 200-480 V, ATEX, IECEx

MPN3RW5513-1HF04
Active

Siemens 3RW5513-1HF04 soft starter, 200-480 V, ATEX, IECEx, UL, CSA, CE, screw terminal, 170 mm width, 275 mm height, 152 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5513-1HF04 — Identification
ParameterValue
Product designationFailsafe soft starters
Product brand nameSIRIUS
3RW5513-1HF04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)5.5 kW
Rated motor power at 230 V (40 °C)3 kW
Rated operational current at 40 °C22.5 A
Rated operational current at 50 °C19.9 A
Rated operational current at 60 °C18.2 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)166 W
3RW5513-1HF04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5513-1HF04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5513-1HF04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5513-1HF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5513-1HF04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5513-1HF04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-area soft starter — ATEX and IECEx certified

The Siemens 3RW5513-1HF04 is a soft starter with explicit ATEX (Yes) and IECEx (Yes) certification, making it suitable for installation in explosive atmospheres where motor starting must not become an ignition source. Rated operating voltage is 200 to 480 V, covering common low-voltage motor supplies in process plants and refineries. Trip classes per IEC 60947-4-2 are selectable: CLASS 10A, 10E (default), 20E, or 30E — the 10A/10E setting matches standard motor acceleration profiles, while 20E/30E accommodate high-inertia loads where extended ramp time is required.

Motor control and protection features

DC braking (Yes) enables rapid stopping of motors with high residual flux, useful on conveyors or centrifuges where coast-down time must be minimized. Voltage ramp (Yes) and pump ramp down (Yes) allow controlled acceleration and deceleration — the pump ramp down reduces water hammer in pipeline applications. Breakaway pulse (Yes) delivers a momentary torque boost to break stalled loads free before the soft-start ramp engages. Torque control (Yes) provides closed-loop regulation of motor torque during start and stop, improving repeatability for process-critical drives. Motor heating (Yes) and service factor of 1.15 allow the starter to account for motor thermal capacity during overload conditions.

Fieldbus connectivity and diagnostics

Supports PROFIBUS (Yes), Modbus RTU (Yes), Modbus TCP (Yes), and EtherNet/IP (Yes) — the fieldbus selection is made via the optional communication module, not hardwired, so the same base unit adapts to different plant networks. PROFIenergy (Yes) enables coordinated energy management when paired with a PROFINET high-feature communication module, allowing the starter to pause during production breaks. Diagnostic tools include an event list (Yes), error logbook (Yes), and trace function (Yes) — the trace captures start/stop current profiles for commissioning or fault analysis without an external data logger. Analog output (Yes) provides a 4-20 mA (default) or 0-10 V signal proportional to motor current, feeding directly into a PLC analog input or panel meter for local indication.

Installation and clearance requirements

Dimensions: 170 mm width, 275 mm height, 152 mm depth — the unit occupies a standard panel footprint with screw terminal connections (Yes) for power and control wiring. Minimum clearance around the device: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides — these ensure adequate airflow for the internal heatsink and prevent thermal derating.

UL approval (Yes), CSA approval (Yes), and CE marking (Yes) cover North American and European regulatory acceptance — the ATEX and IECEx certifications add hazardous-location compliance per IEC 60079 series. Accuracy class 5 per IEC 61557-12 applies to the integrated current measurement — suitable for motor protection and energy monitoring without an external CT. B10d value of 1,588,000 cycles indicates the expected number of operations until 10% of a population fails — relevant for safety-related applications where the starter's reliability data supports SIL calculations. Fail-safe state (Yes) is open load circuit — on loss of control power or internal fault, the output contacts open, de-energizing the motor by default.

Frequently asked questions

What does the ATEX certification on this soft starter mean?

ATEX (Yes) and IECEx (Yes) certification means the 3RW5513-1HF04 is approved for installation in potentially explosive atmospheres per the ATEX directive and IECEx scheme. This covers gas and dust zones where the soft starter's electrical components must not ignite the surrounding atmosphere during normal operation or fault conditions.

MPN