Specifications

3RW5514-1HA04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5514-1HA04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)229 W
3RW5514-1HA04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5514-1HA04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5514-1HA04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5514-1HA04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5514-1HA04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5514-1HA04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What this soft starter does on a motor line

The Siemens 3RW5514-1HA04 is a solid-state soft starter in the SIRIUS 3RW55 family, sized for three-phase induction motors on a 200-480 V supply. It ramps voltage up during start to limit inrush current and torque, then bypasses internally once the motor is at speed — no external contactor needed for the run path. Trip Class is selectable: CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2. That means you match the overload curve to the load — 10A for normal-start pumps and fans, 20E or 30E for high-inertia loads like centrifuges or crushers that need a longer acceleration ramp without nuisance tripping. ATEX and IECEx certification are both marked Yes.

Fieldbus and control integration

Communication is handled onboard: PROFIBUS DP, Modbus RTU, Modbus TCP, and EtherNet/IP are all supported. PROFIenergy is supported when paired with a PROFINET communication module. That lets the drive park the motor during idle periods and log energy data — useful on conveyor lines or machine tools where the spindle stops between cycles. Analog output is configurable as 4-20 mA (default) or 0-10 V, so you can feed motor current or torque to a PLC analog input or a panel meter without a separate transducer.

Dimensions are 170 mm wide, 275 mm high, 152 mm deep. Power terminals accept 2x (1.0-2.5 mm²) and 2x (2.5-10 mm²) solid or stranded copper. Screw terminals throughout — no spring-cage on this variant, so factor in torque-driver time if your shop is all push-in.

Frequently asked questions

Does 3RW5514-1HA04 support PROFIBUS DP communication?

Yes, PROFIBUS DP is supported onboard. The unit also supports Modbus RTU, Modbus TCP, and EtherNet/IP.

What is the ATEX rating on the 3RW5514-1HA04?

ATEX certification is marked Yes, along with IECEx. This soft starter is approved for installation in explosive atmospheres when mounted in a suitable enclosure.

Where can I buy 3RW5514-1HA04 and what is the price?

This unit is sourced to order; availability and pricing are confirmed at quote time. Submit an RFQ for current lead time and commercial terms.

MPN
3RW5514-1HA04