Siemens 3RW5514-1HF04 Soft Starter, 200-480 V, ATEX

MPN3RW5514-1HF04
Active

Siemens 3RW5514-1HF04 soft starter, 200-480 V rated voltage, ATEX & IECEx certified, trip class 10A/10E per IEC 60947-4-2, PROFIBUS/Modbus/EtherNet/IP, UL/CSA, 152x170x275 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5514-1HF04 — Identification
ParameterValue
Product designationFailsafe soft starters
Product brand nameSIRIUS
3RW5514-1HF04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)229 W
3RW5514-1HF04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5514-1HF04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5514-1HF04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5514-1HF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5514-1HF04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5514-1HF04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What this soft starter carries for hazardous-area duty

The 3RW5514-1HF04 carries both ATEX and IECEx certification, so it can be installed in Zone 1 or Zone 2 gas environments and Zone 21 or Zone 22 dust areas — the safe state on fault is an open load circuit, which prevents stored energy from igniting the atmosphere. Rated voltage spans 200 to 480 V, covering common global motor voltages from 208 V North American to 400 V IEC without a separate tap changer.

Overload protection and trip class selection

You can also select 20E or 30E for higher-inertia loads where a longer acceleration time is needed without nuisance tripping. The accuracy class is 5 based on IEC 61557-12, so current measurement error stays within ±5% of reading — tight enough for energy monitoring without a separate CT.

Fieldbus and analog feedback for line integration

Onboard PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP mean it talks to most PLCs without an external gateway — the commissioning engineer sets the IP or node address and the soft starter appears in the device tree. An analog output configurable as 4-20 mA or 0-10 V feeds motor current, voltage, or power to a local panel meter or analog input card — useful when the fieldbus isn't commissioned yet.

Motor control features that matter for pump and conveyor duty

DC braking stops the rotor quickly without a mechanical brake — critical spare for conveyors where coast-to-stop is too long. Voltage ramp and pump ramp down reduce pressure surges in pumping systems, extending seal and pipe life. Torque control and breakaway pulse handle high-breakaway loads like crushers or mixers — the pulse breaks the rotor free, then torque control brings it up to speed smoothly. Motor heating protection models the thermal state of the motor during start and stop cycles, not just running overload — this prevents restarts when the motor is still hot from a previous start.

Panel fit and clearance dimensions

The unit measures 170 mm wide, 275 mm high, and 152 mm deep. Side clearance to adjacent devices is 5 mm; upwards clearance is 100 mm; forwards clearance is 10 mm; downwards clearance is 75 mm; backwards clearance is 0 mm — meaning it can sit flush against the back panel.

Safety and compliance documentation

CE marking, UL approval, and CSA approval are all listed — the unit carries the required marks for European and North American installations. The B10d value is 1,588,000, which feeds into the safety function's PFHd calculation per IEC 61508. The service factor is 1.15, so the soft starter can continuously deliver 115% of its rated current without tripping — matching NEMA motor service factors.

Frequently asked questions

What does the ATEX certification on 3RW5514-1HF04 cover?

The ATEX certification means the soft starter is approved for use in potentially explosive atmospheres per EU Directive 2014/34/EU. The safe state on fault is an open load circuit, which removes ignition energy from the output terminals.