Siemens 3RW5514-3HF04 — Soft Starters

Siemens 3RW5514-3HF04 Soft Starter, ATEX, 200-480V

MPN3RW5514-3HF04
Active

Siemens 3RW5514-3HF04 soft starter, ATEX and IECEx certified, rated 200-480 V, trip class CLASS 10A/10E/20E/30E per IEC 60947-4-2, PROFIBUS/Modbus/EtherNet/IP, UL/CSA approved.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5514-3HF04 — Identification
ParameterValue
Product designationFailsafe soft starters
Product brand nameSIRIUS
3RW5514-3HF04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)229 W
3RW5514-3HF04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5514-3HF04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5514-3HF04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5514-3HF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5514-3HF04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5514-3HF04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-area motor starting with ATEX and IECEx

The Siemens 3RW5514-3HF04 is a soft starter carrying both ATEX and IECEx certification, making it suitable for motor starting in potentially explosive atmospheres where standard soft starters cannot be used. Rated for 200-480 V supply, it covers the common industrial voltage range across Europe, Asia, and North America without needing a separate transformer tap.

Fieldbus integration and control flexibility

This soft starter supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP natively, so it drops into most common industrial networks without a separate gateway module. The analog output can be configured as 4-20 mA or 0-10 V, providing motor current or torque feedback directly to the PLC or drive controller for closed-loop monitoring. Built-in DC braking, voltage ramp, pump ramp down, torque control, and breakaway pulse give you application-specific starting and stopping profiles — pump ramp down prevents water hammer, breakaway pulse cracks high static friction loads.

Safety functions and diagnostic depth

One integrated fail-safe output provides a safe state with open load circuit, suitable for safety-related shutdowns in machinery guarding or process safety applications. The B10d value of 1,588,000 cycles supports reliability calculations for safety circuits per IEC 61508, useful when the soft starter is part of a safety function. Diagnostic tools include an event list, error logbook, and trace function — the trace captures motor current and voltage waveforms during starting events for troubleshooting intermittent faults. Motor heating protection with a service factor of 1.15 allows continuous operation at 115% of rated current without tripping, matching motor nameplate service factors common in pump and fan applications.

Approvals and compliance documentation

CE marking, UL approval, and CSA approval are listed, covering European and North American regulatory requirements for industrial control equipment. ATEX and IECEx certification are explicitly stated, so the unit is documented for installation in Zone 1 or Zone 2 gas atmospheres and Zone 21 or Zone 22 dust atmospheres — the specific gas group and temperature class should be verified against the installation certificate. Firmware update capability is supported, allowing field upgrades without replacing the hardware unit.

Mounting dimensions and wiring

The unit measures 170 mm wide, 275 mm high, and 152 mm deep — plan for a backpanel area roughly 170 x 275 mm plus clearance: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. Power and control wiring uses solid conductors: two terminals accept 1.0-2.5 mm² and two accept 2.5-10 mm² — no screw terminals, so the connection type should be confirmed for the specific terminal design.

Frequently asked questions

What ATEX certification does 3RW5514-3HF04 carry?

ATEX certification is listed as Yes, alongside IECEx certification, making this soft starter suitable for motor starting in hazardous areas where explosive atmospheres may be present.

What fieldbus protocols does 3RW5514-3HF04 support?

PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all supported natively, along with PROFINET and PROFINET High-Feature communication modules for PROFIenergy.