Skip to main content
Siemens 3RW5515-1HA14 — Soft Starters

Siemens 3RW5515-1HA14 Soft Starter, ATEX, 200-480 V

MPN3RW5515-1HA14
Active

Siemens 3RW5515-1HA14 soft starter, ATEX/IECEx certified, rated 200-480 V, selectable trip class 10A/10E/20E/30E per IEC 60947-4-2, voltage ramp, PROFIBUS/Modbus/EtherNet/IP, 275x170x152 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5515-1HA14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5515-1HA14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)11 kW
Rated motor power at 230 V (40 °C)5.5 kW
Rated operational current at 40 °C43.3 A
Rated operational current at 50 °C39 A
Rated operational current at 60 °C33.9 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)309 W

Control & Connection

3RW5515-1HA14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5515-1HA14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5515-1HA14 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5515-1HA14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5515-1HA14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s

Electrical

3RW5515-1HA14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-area motor starting with ATEX certification

The Siemens 3RW5515-1HA14 is a soft starter with ATEX and IECEx certification, meaning it is approved for direct installation in potentially explosive atmospheres — a requirement for motor starting in chemical, oil & gas, or grain-handling environments. The ATEX marking and IECEx listing cover both gas and dust zones, so this unit can serve as the primary motor controller inside a classified area without an external purge or isolation barrier. The wide input range also simplifies stocking for multi-site maintenance programs.

Selectable trip class and starting profiles

Trip class is selectable from 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. Class 10A provides the fastest overload protection — ideal for high-inertia loads where the motor must accelerate quickly without overheating the windings. Class 30E allows a longer start time for heavy loads like crushers or centrifuges. The default 10E setting matches most standard motor applications. Starting profiles include voltage ramp, breakaway pulse, and pump ramp down. The breakaway pulse delivers a short torque boost to break static friction on conveyors or mixers before the ramp begins. Pump ramp down gradually reduces speed to prevent water hammer in pumping systems — a feature often specified in water/wastewater installations.

Fieldbus connectivity and analog feedback

Onboard fieldbus support includes PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. PROFIenergy is supported with PROFINET communication modules for energy management during idle periods. An analog output provides motor current or power feedback as 4-20 mA (default) or 0-10 V, configurable via parameters. This signal feeds directly into a PLC analog input or SCADA system for real-time load monitoring without a separate transducer.

Physical integration and clearance requirements

Dimensions are 275 mm high, 170 mm wide, and 152 mm deep. Mounting requires 100 mm upward clearance, 10 mm forward, 0 mm backward, 75 mm downward, and 5 mm at the sides. These clearances are tight enough to fit into a standard 600 mm deep enclosure with room for cable ducts. Screw terminals accept 2x (1.0-2.5 mm²) and 2x (2.5-10 mm²) solid conductors.

CE marking confirms conformity with EU directives for industrial equipment. UL approval and CSA approval cover North American installations — the soft starter carries both marks, so it can be specified for UL 508A panels without additional component evaluation. Accuracy class 5 per IEC 61557-12 applies to the built-in current measurement for energy monitoring.

Frequently asked questions

Where can I buy the 3RW5515-1HA14 and get a price?

No stock-holding claim is made — each order is sourced from the supply channel.

What ATEX certification does the 3RW5515-1HA14 carry?

The soft starter carries ATEX and IECEx certification for use in potentially explosive atmospheres. This covers both gas and dust hazardous zones, allowing direct installation without external purge systems.

MPN