Siemens 3RW5521-1HA16 — Soft Starters

Siemens 3RW5521-1HA16 Soft Starter, 200-690V, ATEX, Active

MPN3RW5521-1HA16
Active

Siemens 3RW5521-1HA16 soft starter, 200-690 V, ATEX certified, Class 10A/10E/20E/30E trip, PROFIBUS/Modbus/EtherNet/IP, 185 x 306 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5521-1HA16 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5521-1HA16 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)11 kW
Rated motor power at 230 V (40 °C)5.5 kW
Rated operational current at 40 °C43.3 A
Rated operational current at 50 °C39 A
Rated operational current at 60 °C33.9 A
Rated insulation voltage690 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)283 W

Control & Connection

3RW5521-1HA16 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5521-1HA16 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes; Only up to 600 V operating voltage
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5521-1HA16 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.5 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5521-1HA16 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5521-1HA16 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s

Electrical

3RW5521-1HA16 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

ATEX-rated motor starting for hazardous zones

This Siemens 3RW5521-1HA16 soft starter carries ATEX and IECEx certification, meaning it can be specified for motor starting in potentially explosive atmospheres without an additional isolation barrier. The ATEX marking covers gas and dust groups per the ATEX directive; the IECEx listing provides the global equivalent for jurisdictions that follow the IECEx scheme. The wide voltage window means one part number can be stocked for multi-voltage plants.

Trip class and motor protection coordination

The trip class is selectable from CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2. Class 10A is the standard for standard-start applications; Class 20E or 30E accommodates high-inertia loads like centrifuges or crushers where the start time exceeds 10 seconds. The selector is parameterized via the onboard interface. Built-in motor heating and DC braking allow the soft starter to handle both start and stop control without external contactors for the braking function. The voltage ramp and pump ramp down reduce mechanical shock on the load and piping. Accuracy Class 5 per IEC 61557-12 applies to the integrated current measurement — sufficient for motor protection without a separate CT. The service factor of 1.15 means the starter can run the motor at 115% of rated current continuously without tripping, matching typical NEMA motor service factors.

Fieldbus and control integration

The 3RW5521-1HA16 supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP natively — no separate communication module required for these protocols. PROFINET with PROFIenergy is available via an optional communication module. This multi-protocol capability lets the starter drop into existing plant networks without a gateway. Analog output configurable as 4-20 mA or 0-10 V provides a real-time motor current signal to a PLC or SCADA. The event list and error logbook store the last several fault events with timestamps, useful for diagnosing intermittent trips without a continuous connection. Firmware update capability via the fieldbus interface means the starter can be upgraded in the field without replacing hardware. Four parameter sets allow quick changeover between different motor configurations or process recipes.

Mounting and clearance for panel layout

The unit measures 185 mm wide, 306 mm high, and 203 mm deep. Required clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. The zero rear clearance means it can be mounted flush against a back panel, saving depth in shallow enclosures. Screw terminals are standard for power and control wiring — no special crimp tooling needed. The terminal layout follows Siemens SIRIUS standard spacing, compatible with common busbar systems and feeder terminals.

Compliance and approvals for global shipments

CE marking covers the EU low-voltage and EMC directives. UL approval and CSA approval cover North American installations. ATEX and IECEx cover hazardous locations. This combination of approvals means the starter can be shipped to most industrial markets without additional certification work.

Frequently asked questions

What ATEX certification does the 3RW5521-1HA16 carry?

The soft starter is ATEX certified and also carries IECEx certification. This covers use in potentially explosive atmospheres per the ATEX directive and the IECEx scheme. The specific gas/dust group and temperature class should be verified against the nameplate for the exact installation zone.

What are the panel clearance requirements for the 3RW5521-1HA16?

Required clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. The zero rear clearance allows flush mounting against the back panel. Overall dimensions are 185 mm wide x 306 mm high x 203 mm deep.

What fieldbus protocols does the 3RW5521-1HA16 support natively?

The starter supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP without additional communication modules. PROFINET with PROFIenergy requires an optional communication module. The analog output can be configured as 4-20 mA or 0-10 V for direct PLC connection.

MPN
3RW5521-1HA16