Siemens 3RW5524-1HA06 — Soft Starters

Siemens 3RW5524-1HA06 Soft Starter, 200-690 V, ATEX, IECEx

MPN3RW5524-1HA06
Active

Siemens 3RW5524-1HA06 soft starter, 200-690 V, ATEX and IECEx certified, Class 10A/10E trip, screw terminals, PROFIBUS, Modbus RTU/TCP, EtherNet/IP.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5524-1HA06 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5524-1HA06 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)22 kW
Rated motor power at 230 V (40 °C)11 kW
Rated operational current at 40 °C81.4 A
Rated operational current at 50 °C72 A
Rated operational current at 60 °C62.7 A
Rated insulation voltage690 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)504 W
3RW5524-1HA06 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5524-1HA06 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes; Only up to 600 V operating voltage
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5524-1HA06 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.5 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5524-1HA06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5524-1HA06 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5524-1HA06 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

ATEX and IECEx certified for hazardous-area motor starting

The 3RW5524-1HA06: This soft starter carries both ATEX and IECEx certification, meaning it is approved for use in potentially explosive atmospheres — a requirement for pump and fan drives in oil/gas, chemical, and grain-handling installations.

Trip class selection and motor protection

Configurable trip classes — Class 10A, 10E (default), 20E, or 30E per IEC 60947-4-2 — let you match the thermal overload curve to the motor start profile: Class 10A for short-duration starts (centrifugal pumps), Class 30E for high-inertia loads (conveyors, crushers). The accuracy class is 5 per IEC 61557-12, meaning the current measurement error stays within ±5 % of reading — tight enough for reliable overload protection without nuisance tripping.

Fieldbus connectivity and control features

Built-in PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP support means this unit drops into most common industrial networks without an external gateway — the integrator just sets the node address and baud rate. PROFIenergy is supported via PROFINET communication modules, enabling energy-saving pauses during idle periods — useful in automated production lines with intermittent duty cycles.

Motor control functions for demanding applications

Includes DC braking, combined braking, pump ramp down, breakaway pulse, and torque control — features that handle stopping pump columns without water hammer, breaking high-inertia loads, and starting sticky or seized machinery. The voltage ramp start reduces mechanical shock on the driveline, while the breakaway pulse delivers a short torque boost to overcome static friction before ramping to full speed.

Panel integration and mounting clearances

Required clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, 0 mm behind. Screw terminals simplify wiring — no special crimp tools needed for the power connections. The service factor of 1.15 allows continuous operation at 115 % of rated current without tripping, matching typical NEMA motor service factors.

Global approvals and compliance documentation

CE marking for European markets, UL and CSA approval for North America — this unit meets the certification requirements for most industrial installations worldwide. ATEX and IECEx certification is listed directly on the unit, so it can be installed in Zone 1 or Zone 2 hazardous areas without additional external protection barriers.

Frequently asked questions

Does the 3RW5524-1HA06 support Modbus TCP?

Yes, it supports Modbus TCP, Modbus RTU, PROFIBUS, and EtherNet/IP — all built-in without requiring an external communication module.

What trip classes are available on the 3RW5524-1HA06?

The unit is configurable for Class 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. Class 10A suits short-duration starts; Class 30E handles high-inertia loads.

What are the mounting clearances required for the 3RW5524-1HA06?

Minimum clearances: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind the unit. These ensure adequate airflow for cooling.

MPN
3RW5524-1HA06