Siemens 3RW5525-1HA06 — Soft Starters

Siemens 3RW5525-1HA06 Soft Starter, 200-690 V, ATEX

MPN3RW5525-1HA06
Active

Siemens 3RW5525-1HA06 soft starter, 200-690 V, ATEX & IECEx certified, trip class 10A/10E/20E/30E, screw terminals, 185 x 306 x 203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5525-1HA06 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5525-1HA06 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)30 kW
Rated motor power at 230 V (40 °C)18.5 kW
Rated operational current at 40 °C109 A
Rated operational current at 50 °C96 A
Rated operational current at 60 °C87.5 A
Rated insulation voltage690 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)732 W
3RW5525-1HA06 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5525-1HA06 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes; Only up to 600 V operating voltage
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5525-1HA06 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.9 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5525-1HA06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5525-1HA06 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5525-1HA06 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class flexibility and voltage range

The 3RW5525-1HA06: Trip class is configurable between CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. The rated voltage covers 200 to 690 V, which handles most global supply systems from 208 V to 600 V without a transformer.

Fieldbus connectivity and control features

Communication options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, plus PROFINET with PROFIenergy capability when fitted with the appropriate communication module. The unit also supports DC braking and combined braking, which can be configured to stop the motor faster than coasting — useful for conveyors or pumps where backspin is undesirable. Torque control and a breakaway pulse are available for starting high-friction loads like screw compressors or belt conveyors.

Temperature derating and panel clearance

Minimum clearance around the unit: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm sideways, and 0 mm backwards. That means the unit can be mounted flush against the back panel, saving depth in the enclosure. Dimensions are 185 mm wide, 306 mm high, and 203 mm deep.

Approvals and compliance documentation

CE, UL, and CSA approvals are all confirmed on this order code, covering European and North American installations. Accuracy class 5 per IEC 61557-12 applies to the integrated metering function. The unit also includes a service factor of 1.15, so it can handle continuous overloads up to 115 % of the rated current without tripping.

Frequently asked questions

What trip classes can the 3RW5525-1HA06 be set to?

Trip class is configurable to CLASS 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. The default is 10E, which covers most standard motor starts. For high-inertia loads requiring longer start times, select 20E or 30E.

What fieldbus protocols does the 3RW5525-1HA06 support?

It supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP directly. PROFINET with PROFIenergy is available when used with the appropriate PROFINET High-Feature communication module.

MPN
3RW5525-1HA06