Siemens SIRIUS 3RW5526-1HF04 soft starter, 200-480 V rated voltage, ATEX/IECEx approved, trip class 10A/10E/20E/30E per IEC 60947-4-2, screw terminals, 306 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RW5526-1HF04 — Identification
ParameterValue
Product designationFailsafe soft starters
Product brand nameSIRIUS
3RW5526-1HF04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)37 kW
Rated motor power at 230 V (40 °C)22 kW
Rated operational current at 40 °C133 A
Rated operational current at 50 °C118 A
Rated operational current at 60 °C107 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)921 W
3RW5526-1HF04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5526-1HF04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5526-1HF04 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight7.15 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5526-1HF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5526-1HF04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5526-1HF04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5526-1HF04 is a SIRIUS soft starter with a rated voltage range of 200 to 480 V, covering the common three-phase motor voltages across 208 V, 230 V, 400 V, and 480 V systems without needing a separate tap changer. The trip class is field-selectable among CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2 — this means you match the overload protection curve to the motor's starting characteristic: CLASS 10A for standard-start pumps and fans, 20E or 30E for high-inertia loads like centrifuges or crushers that need a longer acceleration ramp. The ATEX and IECEx approvals (both Yes) certify the device for use in explosive atmospheres (Zone 1/21 or Zone 2/22) when paired with appropriately rated motor and cabling, so it directly replaces a standard soft starter in a hazardous-area motor control center without adding an external isolation barrier.

Fieldbus and control integration

Communication is handled natively: Modbus RTU (RS-485), Modbus TCP, PROFIBUS, and EtherNet/IP are all supported on this order code. That means the starter connects directly to a PLC rack or plant DCS without an external gateway — the Modbus TCP port plugs into a standard switch, and the PROFIBUS DP interface uses the same connector as the rest of the SIRIUS family. The analog output is configurable for 4-20 mA or 0-10 V, giving the control system a live motor current signal for trending or alarming. For commissioning, the firmware is field-updatable, and the integrated event list and error logbook store the last several trips with time stamps — useful for diagnosing intermittent overloads on a remote line.

Panel layout dimensions

The enclosure dimensions are 306 mm height, 185 mm width, and 203 mm depth — a standard SIRIUS frame size that fits a 400 mm wide MCC bucket or a 600 mm deep enclosure with the door closed. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. These are the minimum free-air gaps for natural convection cooling; if the starter is mounted in a sealed cabinet or next to other heat-generating devices, expect to derate the continuous current or add forced ventilation.

No lifecycle status is on record for this order code — the part is not flagged as obsolete, NRND, or end-of-life in the available data. That means it remains a current catalog item in the SIRIUS soft starter family.

Frequently asked questions

What is the rated current of the 3RW5526-1HF04 soft starter?

Buyers need to confirm it matches their motor load requirements.

Does the 3RW5526-1HF04 support 24V AC/DC control voltage?

Control voltage compatibility is critical for integration into existing panels.

Is the 3RW5526-1HF04 fail-safe and ATEX approved?

Safety and hazardous location approvals determine if the part can be used in specific industries.

Where can I buy the 3RW5526-1HF04 and what is the lead time?

Procurement needs to know availability and delivery schedule to avoid production delays.

What are the exact dimensions of the 3RW5526-1HF04 for panel layout?

Mechanical fit is essential for design engineers planning cabinet space.

Is there a direct replacement or equivalent for the 3RW5526-1HF04 from other brands?

Sourcing alternatives helps mitigate supply chain risks and compare costs.

MPN
3RW5526-1HF04