Siemens 3RW5527-1HA06 — Soft Starters

Siemens 3RW5527-1HA06 Soft Starter, 200-690 V, ATEX, Active

MPN3RW5527-1HA06
Active

Siemens 3RW5527-1HA06 soft starter, 200-690 V, ATEX and IECEx certified, Class 10A/10E/20E/30E trip class, screw terminals, active production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5527-1HA06 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5527-1HA06 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)45 kW
Rated motor power at 230 V (40 °C)22 kW
Rated operational current at 40 °C161 A
Rated operational current at 50 °C143 A
Rated operational current at 60 °C131 A
Rated insulation voltage690 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)1 065 W
3RW5527-1HA06 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5527-1HA06 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes; Only up to 600 V operating voltage
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5527-1HA06 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight7.15 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5527-1HA06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5527-1HA06 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5527-1HA06 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

200-690 V soft starter with ATEX and trip class flexibility

The Siemens 3RW5527-1HA06 is a soft starter covering a 200-690 V supply range, with ATEX and IECEx certification for use in potentially explosive atmospheres.

Fieldbus, monitoring, and special functions

Supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, plus PROFIenergy for coordinated energy management on PROFINET networks. Analog output configurable as 4-20 mA or 0-10 V for feeding motor current or torque to a PLC or panel meter. Built-in pump ramp down, breakaway pulse for high breakaway torque, DC braking, and combined braking — the breakaway pulse is useful for conveyors or crushers that need a torque spike to unstick the load before ramping.

Mounting and environmental limits

Dimensions are 306 mm high, 185 mm wide, 203 mm deep — screw terminal connections, with 100 mm clearance required above and 75 mm below for airflow; side clearance is 5 mm, forward 10 mm, backward 0 mm (wall-mountable).

Carries CE, UL, and CSA approvals, plus ATEX and IECEx for hazardous locations — the ATEX marking means it can be installed in Zone 1 or Zone 2 gas groups, subject to the installation code. Accuracy Class 5 per IEC 61557-12 for the integrated metering function; service factor 1.15 allows 15 % continuous overload above nameplate current.

Frequently asked questions

What does the ATEX certification mean for this soft starter?

The ATEX marking (Yes) indicates the 3RW5527-1HA06 is certified for installation in potentially explosive atmospheres per the ATEX directive, typically Zones 1 and 2 for gas. The IECEx certification provides international acceptance. This is a key differentiator — most soft starters in this class lack hazardous-location approval.

What trip classes are available and how do I set them?

The unit supports Class 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. The trip class is parameterized via the onboard interface or fieldbus — no physical heater elements to swap. Use Class 10A for standard motor starts under 10 seconds, Class 30E for high-inertia loads that need a longer acceleration ramp.

Can I monitor motor current or torque through this soft starter?

Yes, the analog output can be configured as 4-20 mA or 0-10 V to reflect motor current, torque, or other parameters. The unit also includes an event list, error logbook, and trace function for diagnostics — useful for commissioning and fault analysis.

What are the clearance requirements for mounting?

Allow 100 mm above, 75 mm below, 5 mm at the sides, 10 mm forward, and 0 mm backward (wall-mountable). The screw terminal connections are at the front; the 306 mm height and 185 mm width fit standard 600 mm-wide enclosures with room for wiring ducts.