Skip to main content
Siemens 3RW5527-1HF04 — Soft Starters

Siemens 3RW5527-1HF04 Soft Starter, 200-480 V, ATEX, IECEx

MPN3RW5527-1HF04
Active

Siemens 3RW5527-1HF04 soft starter, 200-480 V, ATEX and IECEx certified, trip class 10A/10E/20E/30E, multiple fieldbus interfaces, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5527-1HF04 — Identification
ParameterValue
Product designationFailsafe soft starters
Product brand nameSIRIUS
3RW5527-1HF04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)45 kW
Rated motor power at 230 V (40 °C)22 kW
Rated operational current at 40 °C161 A
Rated operational current at 50 °C143 A
Rated operational current at 60 °C131 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)1 065 W
3RW5527-1HF04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5527-1HF04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5527-1HF04 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight7.15 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5527-1HF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5527-1HF04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5527-1HF04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

ATEX certification and motor control features

This Siemens 3RW5527-1HF04 soft starter carries ATEX and IECEx certification, meaning it is approved for use in potentially explosive atmospheres — a requirement often overlooked until the site safety audit flags the motor starter. The trip class is configurable between CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. CLASS 10A suits standard-starting loads like pumps and fans; CLASS 30E handles high-inertia loads such as centrifuges or crushers where the acceleration time exceeds 10 seconds.

Fieldbus integration and control interfaces

On-board fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. The analog output is configurable as 4-20 mA (default) or 0-10 V, feeding motor current or torque signals directly to a PLC analog input without an external signal conditioner. PROFIenergy support allows the starter to participate in coordinated energy-saving shutdowns during production pauses on PROFINET networks — a feature that pays for itself in facilities with scheduled idle periods.

Mounting dimensions and panel layout

The unit measures 185 mm wide, 306 mm high, and 203 mm deep. Plan for 100 mm clearance above, 75 mm below, 10 mm in front, and 5 mm at the sides — the backwards clearance is zero, so it can sit flush against the back panel. Screw terminals are standard for power and control wiring — no special crimp tooling required, which keeps installation straightforward for panel builders.

Advanced motor control and diagnostics

Voltage ramp, torque control, and breakaway pulse give the starter the ability to handle difficult loads: breakaway pulse clears stuck pump impellers, torque control limits inrush on conveyors, and pump ramp down prevents water hammer on pipeline shutdowns. DC braking provides controlled stopping for high-inertia loads without a separate braking contactor or resistor bank. On-board diagnostics include an event list, error logbook, trace function, and motor heating model — useful for commissioning engineers troubleshooting a soft-start fault without a laptop.

CE marking, UL approval, and CSA approval cover the major North American and European regulatory jurisdictions. The accuracy class is 5 per IEC 61557-12, which defines the measurement uncertainty for the integrated current and voltage sensing. The service factor is 1.15, meaning the starter can continuously deliver 115 % of its rated current without exceeding thermal limits — useful for applications where the motor runs near its full load amp rating.

Frequently asked questions

What is the ATEX certification on this soft starter?

The 3RW5527-1HF04 carries ATEX and IECEx certification, approving it for use in explosive atmospheres as defined by the ATEX directive and IECEx scheme.

What fieldbus protocols does the 3RW5527-1HF04 support?

On-board protocols include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP.

What compliance documentation does Siemens provide for 3RW5527-1HF04?

The starter carries CE marking, UL approval, and CSA approval.

MPN
3RW5527-1HF04