Siemens 3RW5534-6HA14 — Soft Starters

Siemens 3RW5534-6HA14 Soft Starter, 200-480V, Class 10A/10E/

MPN3RW5534-6HA14
Active

Siemens SIRIUS 3RW55 soft starter, order code 3RW5534-6HA14, rated 200-480 V, trip class 10A/10E/20E/30E per IEC 60947-4-2, ATEX and IECEx certified, screw terminals, PROFIBUS/Modbus RTU/Modbus TCP/EtherNet/IP.

$3,724.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5534-6HA14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5534-6HA14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)55 kW
Rated motor power at 230 V (40 °C)30 kW
Rated operational current at 40 °C196 A
Rated operational current at 50 °C175 A
Rated operational current at 60 °C154 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)1 279 W
3RW5534-6HA14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5534-6HA14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5534-6HA14 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight6.85 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5534-6HA14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5534-6HA14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5534-6HA14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5534-6HA14 is a SIRIUS 3RW55 soft starter rated for 200... 480 V supply. The trip class is selectable: CLASS 10A / 10E (default) / 20E / 30E, per IEC 60947-4-2. Class 20E or 30E buys more time for high-inertia loads (centrifuges, fans) that need a longer ramp. The default 10E is a safe starting point for most general-purpose induction motors. ATEX and IECEx certification means this unit is approved for installation in explosive atmospheres — it can sit in Zone 1 or Zone 2 gas groups or Zone 21/22 dust areas, as long as the upstream protection and enclosure match the area classification. The approvals cover the soft starter itself, not the motor circuit; the motor and cabling still need their own Ex compliance. Fieldbus options are built in: PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. That covers the three common industrial Ethernet protocols plus the legacy PROFIBUS, so it drops into a Rockwell, Siemens, or Schneider control architecture without an external gateway. The analog output is configurable 4... 20 mA (default) or 0... 10 V, useful for feeding a local panel meter or a remote SCADA input. Screw terminals — no spring-cage option on this variant. Factor in the extra wiring time if your panel shop is standardised on push-in or cage-clamp blocks. Dimensions: 306 mm high, 185 mm wide, 203 mm deep. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, 0 mm backwards. That backwards zero means it can sit flush against a backplate — useful in tight enclosures.

Motor control features and protection

DC braking is included — energises the motor windings with DC to stop rotation faster than coast-to-rest, useful on conveyors or saws where residual spin is a safety or process issue. Voltage ramp gives a controlled acceleration profile; torque control lets you limit starting torque to avoid mechanical shock on geared loads. Breakaway pulse delivers a short high-torque burst to break static friction on stuck pumps or crushers before the ramp begins. Pump ramp down is a dedicated deceleration profile that reduces water hammer on pump stop. Motor heating provides pre-heating for motors in cold environments. Service factor 1.15 means the soft starter can handle a 15% continuous overload above nameplate without tripping — match this to the motor's own service factor. Accuracy class 5 per IEC 61557-12 applies to the measurement functions (current, voltage, power). That's a ±5% accuracy band — adequate for protection and basic monitoring, not for revenue-grade metering. Event list, error logbook, and trace function are available for diagnostics via the fieldbus or the local HMI.

Approvals on record: CE marking, UL approval, CSA approval, ATEX, IECEx. These cover the European, North American, and international hazardous-location markets. No RoHS or REACH statement is in the evidence, but standard Siemens industrial products typically comply — verify against the manufacturer's declaration if your compliance audit requires it.

Frequently asked questions

What is the closest alternative to 3RW5534-6HA14 in this family?

The closest sibling is the 3RW5534-6HA04, which is the same soft starter without the integrated fieldbus modules. The 6HA14 adds PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP on-board; the 6HA04 has no fieldbus and requires an external communication module if network control is needed. If you don't need the fieldbus, the 6HA04 saves cost and panel space. If you need any of those protocols, the 6HA14 is the direct fit.

MPN
3RW5534-6HA14