Specifications

3RW5536-6HA04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5536-6HA04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)90 kW
Rated motor power at 230 V (40 °C)45 kW
Rated operational current at 40 °C296 A
Rated operational current at 50 °C265 A
Rated operational current at 60 °C244 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)2 038 W
3RW5536-6HA04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5536-6HA04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5536-6HA04 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight9.1 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5536-6HA04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5536-6HA04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5536-6HA04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5536-6HA04 is a solid-state soft starter rated for a supply voltage of 200 to 480 V, designed for three-phase induction motor starting in industrial control panels. It carries ATEX and IECEx certification for use in potentially explosive atmospheres, and its trip class is selectable among CLASS 10A, 10E (default), 20E, or 30E according to IEC 60947-4-2 — meaning you can match the overload protection curve to the motor's thermal capacity and the starting duty cycle.

Fieldbus & Analog Feedback

This soft starter supports Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS natively, so it drops into most common automation networks without an external gateway. The analog output can be configured for 4-20 mA or 0-10 V, giving the PLC a direct process-variable signal for current or torque monitoring. Mounts on a panel backplate — the 306 mm height, 185 mm width, and 203 mm depth require 100 mm clearance above and 75 mm below for ventilation; side clearance is 5 mm. Screw terminals are standard, so no special crimp tooling needed.

Frequently asked questions

Is 3RW5536-6HA04 compatible with Modbus TCP?

Yes, it supports Modbus TCP natively, as well as Modbus RTU, EtherNet/IP, and PROFIBUS.

What is the trip class of 3RW5536-6HA04?

The trip class is selectable: CLASS 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. This lets you set the overload curve to match the motor's thermal limit and starting duration.