Siemens 3RW5544-2HA16 — Soft Starters

Siemens 3RW5544-2HA16 Soft Starter, 200-690 V, ATEX

MPN3RW5544-2HA16
Active

Siemens SIRIUS 3RW5544-2HA16 soft starter, 200–690 V, ATEX/IECEx, trip class 10A/10E/20E/30E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, 393 x 210 x 203 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5544-2HA16 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5544-2HA16 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage690 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)3 176 W
3RW5544-2HA16 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5544-2HA16 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes; Only up to 600 V operating voltage
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5544-2HA16 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight10.2 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5544-2HA16 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5544-2HA16 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5544-2HA16 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class flexibility for motor protection

The 3RW5544-2HA16 offers selectable trip classes: CLASS 10A / 10E (default), 20E, and 30E per IEC 60947-4-2. This lets you match the overload curve to the motor's starting duty — CLASS 10 for high-inertia loads that need a fast trip on stall, CLASS 20 or 30 for longer acceleration times on conveyors or crushers. Rated supply voltage spans 200 to 690 V, covering 400 V and 480 V mains without a tap change. The control voltage accepts 110–250 V at 50 or 60 Hz, so it works across European and North American line frequencies.

Fieldbus and analog feedback for SCADA integration

Built-in PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP mean you can drop this soft starter onto most plant networks without an external gateway. The analog output defaults to 4–20 mA but can be switched to 0–10 V — useful for feeding motor current or torque to a PLC analog input without a separate transducer. The event list and error logbook (with trace function) let you diagnose trip causes from the HMI or SCADA historian, rather than walking to the panel. Firmware updates are field-loadable, so you can apply later feature releases without swapping hardware.

ATEX and IECEx certification for hazardous zones

ATEX and IECEx certification (both listed as Yes) means this soft starter can be installed in gas or dust hazardous areas — typically Zone 2 or Zone 22, depending on the enclosure. The service factor of 1.15 provides a 15 % continuous overload margin above the motor FLA, which helps avoid nuisance trips in borderline applications. DC braking, voltage ramp, pump ramp down, and breakaway pulse are built in — no external add-on modules needed for common pump or conveyor starting profiles.

Mounting dimensions and clearances

The unit measures 393 mm high, 210 mm wide, and 203 mm deep. Minimum clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind. This fits a standard 600 mm deep enclosure with room for wiring ducts.