Skip to main content
Siemens 3RW5544-6HA14 — Soft Starters

Siemens 3RW5544-6HA14 Soft Starter, ATEX, 200-480V

MPN3RW5544-6HA14
Active

Siemens SIRIUS 3RW5544-6HA14 soft starter, ATEX, IECEx, 200-480 V, trip class 10A/10E (default) / 20E / 30E per IEC 60947-4-2, screw terminal, PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, 210 x 393 x 203 mm.

$3,442.97 – $5,186.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RW5544-6HA14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5544-6HA14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)132 kW
Rated motor power at 230 V (40 °C)75 kW
Rated operational current at 40 °C433 A
Rated operational current at 50 °C381 A
Rated operational current at 60 °C346 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)3 176 W
3RW5544-6HA14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5544-6HA14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5544-6HA14 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight10.2 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5544-6HA14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5544-6HA14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5544-6HA14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Soft starter for ATEX and IECEx zones

The Siemens 3RW5544-6HA14 is a SIRIUS soft starter rated for 200-480 V with trip class options CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2. Both ATEX and IECEx certified, it is suited for motor starting in potentially explosive atmospheres where controlled acceleration and deceleration are required. The unit supports DC braking, voltage ramp, pump ramp down, torque control, and a breakaway pulse — covering soft-start, soft-stop, and stall protection for induction motors in hazardous-area conveyors, pumps, and fans.

Fieldbus and parameterization

This soft starter integrates with PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, plus PROFIenergy in conjunction with PROFINET communication modules. The analog output defaults to 4-20 mA or 0-10 V. Four parameterizable sets, an event list, error logbook, and trace function are onboard. Firmware updates are supported. The screw-terminal connection block and the 210 x 393 x 203 mm footprint fit standard panel layouts with 100 mm upward clearance, 75 mm downward, 10 mm forward, 5 mm side, and 0 mm backward.

Frequently asked questions

Does 3RW5544-6HA14 support Modbus RTU?

Yes, Modbus RTU is supported alongside Modbus TCP, EtherNet/IP, and PROFIBUS.

MPN
3RW5544-6HA14