Siemens 3RW5547-2HA04 — Soft Starters

Siemens 3RW5547-2HA04 Soft Starter, ATEX/IECEx, 200-480 V

MPN3RW5547-2HA04
Active

Siemens SIRIUS 3RW5547-2HA04 soft starter, ATEX/IECEx certified, 200-480 V rated voltage, trip class 10A/10E/20E/30E per IEC 60947-4-2, Modbus TCP, PROFIBUS, EtherNet/IP.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RW5547-2HA04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5547-2HA04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)250 kW
Rated motor power at 230 V (40 °C)132 kW
Rated operational current at 40 °C814 A
Rated operational current at 50 °C721 A
Rated operational current at 60 °C658 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)6 400 W
3RW5547-2HA04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5547-2HA04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5547-2HA04 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight10.9 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5547-2HA04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5547-2HA04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5547-2HA04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-Area Deployment

The Siemens 3RW5547-2HA04 soft starter carries both ATEX and IECEx certification, making it suitable for Zone 1/Zone 2 gas and dust atmospheres per IEC 60079. This is not a general-purpose soft starter — confirm the Ex marking matches your area classification before specifying. Rated operating voltage spans 200 to 480 V AC, covering common global industrial supply voltages. The unit is CE, UL, and CSA approved, easing panel acceptance in North American and European installations.

Trip Class and Motor Protection

Trip class is configurable: CLASS 10A / 10E (default), 20E, or 30E per IEC 60947-4-2. CLASS 10A is the standard for standard induction motors; CLASS 20E or 30E suits high-inertia loads like centrifuges or crushers where longer acceleration times are needed. The service factor of 1.15 allows continuous overload margin above nameplate rating. Accuracy Class 5 per IEC 61557-12 means the current measurement error stays within ±5 % of reading — adequate for motor protection but not precision metering.

Fieldbus and Communication

Built-in support for Modbus RTU, Modbus TCP, PROFIBUS, and EtherNet/IP eliminates the need for external gateway modules in most architectures. PROFIenergy is available when paired with PROFINET High-Feature communication modules, allowing energy-efficient shutdown of loads during idle periods. Analog output configurable as 4-20 mA (default) or 0-10 V, usable for retransmitting motor current or load status to a PLC analog input.

Mounting and Environmental

Clearance required: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the side, 0 mm backward — plan your enclosure depth accordingly. If the panel ambient exceeds 40 °C, expect to reduce the rated current or provide forced ventilation.

Frequently asked questions

Where can I buy the Siemens 3RW5547-2HA04 soft starter?

The Siemens 3RW5547-2HA04 is sourced to order through independent distribution. Submit an RFQ to confirm availability and current pricing.

Does the 3RW5547-2HA04 support Modbus TCP and PROFIBUS?

Yes, it supports Modbus RTU, Modbus TCP, PROFIBUS, and EtherNet/IP natively.

What is 3RW5547-2HA04's ATEX certification?

The 3RW5547-2HA04 carries ATEX and IECEx certification for hazardous-area use.

MPN
3RW5547-2HA04