Skip to main content
Siemens 3RW5547-2HA06

Siemens 3RW5547-2HA06 SIRIUS Soft Starter, ATEX, 200-690 V

MPN 3RW5547-2HA06
Active

Siemens SIRIUS 3RW5547-2HA06 soft starter, ATEX & IECEx certified, rated 200-690 V, Trip Class 10A/10E-30E, with Modbus TCP/RTU, PROFIBUS, EtherNet/IP, 393 x 210 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5547-2HA06 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width210 mm
Height393 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15
Digital output version3 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

What this soft starter brings to the panel

The Siemens 3RW5547-2HA06 is a SIRIUS-series soft starter carrying ATEX and IECEx certification. Trip class is configurable from CLASS 10A / 10E (default) through 20E and 30E per IEC 60947-4-2. Rated voltage spans 200 to 690 V. Communication is fully wired for modern factory networks: Modbus RTU, Modbus TCP, PROFIBUS, and EtherNet/IP are all on board. That saves an external gateway and simplifies the control cabinet layout. The unit also supports PROFIenergy in connection with PROFINET Standard and PROFINET High-Feature communication modules, which allows energy-saving pauses during idle periods on automated lines. The 393 x 210 x 203 mm footprint (height x width x depth) plus clearance requirements (100 mm upward, 75 mm downward, 10 mm forward, 5 mm at the side, 0 mm backward) must be factored into the panel layout before cutting the gland plate.

Approvals include CE, UL, and CSA. ATEX and IECEx marks are the main differentiator from standard soft starters.

The adjustable trip class (10A/10E default, 20E, 30E) governs how long the soft starter allows the motor to draw starting current before the thermal model trips. Accuracy class is 5 per IEC 61557-12. Additional motor-control features include DC braking for rapid stopping, voltage ramp for gentle acceleration, pump ramp down to avoid water hammer, torque control, a breakaway pulse to crack stuck loads, and motor heating for anti-condensation in standby. The analog output is configurable as 4-20 mA (default) or 0-10 V, feeding motor current or other process values to a PLC or panel meter. Service factor is 1.15, matching the typical NEMA motor margin.

MPN