Siemens 3RW5553-6HA04 — Soft Starters

Siemens 3RW5553-6HA04 SIRIUS Soft Starter, 200-480V

MPN3RW5553-6HA04
Active

Siemens SIRIUS 3RW5553-6HA04 soft starter, 200-480 V rated, selectable trip classes CLASS 10A / 10E / 20E / 30E per IEC 60947-4-2, ATEX/IECEx certified, screw terminals, 478 x 764 x 241 mm (WxHxD).

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5553-6HA04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5553-6HA04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)400 kW
Rated motor power at 230 V (40 °C)200 kW
Rated operational current at 40 °C1 247 A
Rated operational current at 50 °C1 110 A
Rated operational current at 60 °C1 005 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)9 773 W

Control & Connection

3RW5553-6HA04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5553-6HA04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5553-6HA04 — Mechanical
ParameterValue
Height764 mm
Width478 mm
Depth241 mm
Weight45 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5553-6HA04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5553-6HA04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s

Electrical

3RW5553-6HA04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The 3RW5553-6HA04 is a SIRIUS soft starter from Siemens, rated for a supply of 200 to 480 V. Its trip class is field-selectable among CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. That means you can match the overload protection curve to the starting characteristic of the motor — CLASS 10A for a standard pump or fan, CLASS 20E or 30E for high-inertia loads like a centrifuge or crusher where the start takes longer. The default 10E setting covers most general-purpose induction motors on a conveyor or compressor. It carries ATEX and IECEx certification, so it is approved for use in potentially explosive atmospheres. CE, UL, and CSA approvals are also on file.

The unit measures 478 mm wide, 764 mm high, and 241 mm deep. It mounts with screw terminals for power and control wiring. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 0 mm backwards, and 5 mm at the side. That 100 mm upward gap is critical for airflow — the soft starter draws heat out the top, and blocking that space derates the unit above 40 °C ambient, as noted in the operating range of -25 to +60 °C with derating required at 40 °C or above.

Fieldbus and control features

Communication options are built in: PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all supported. PROFIenergy is also available when paired with PROFINET standard and High-Feature communication modules. That means the soft starter can be integrated into most common industrial networks without an extra gateway. The analog output can be configured as 4-20 mA (default) or 0-10 V. Control features include DC braking, voltage ramp, pump ramp down, torque control, a breakaway pulse for high-friction starts, combined braking, and an auto-reset function after a fault. The remote reset allows clearing a trip from the control room without walking to the panel. An event list, error logbook, and trace function aid in fault isolation — the trace captures parameter trends leading up to a trip, which saves time when diagnosing intermittent overloads on a critical line.

Frequently asked questions

What is the trip class of 3RW5553-6HA04?

The trip class is field-selectable: CLASS 10A, 10E (default), 20E, or 30E, per IEC 60947-4-2. Choose 10A/10E for standard starts, 20E or 30E for high-inertia loads.

Can 3RW5553-6HA04 be used with Modbus TCP?

Yes, Modbus TCP is supported directly on this unit, along with Modbus RTU, PROFIBUS, and EtherNet/IP.

Does 3RW5553-6HA04 support ATEX?

Yes, it carries ATEX certification, meaning it is approved for installation in potentially explosive atmospheres per the ATEX directive.

How to reset 3RW5553-6HA04 after a fault?

The soft starter supports both auto-reset and remote reset. For a manual reset, cycle the control supply or use the remote reset input from a PLC or pushbutton.

Where can I buy 3RW5553-6HA04?

This part is sourced to order. Availability and pricing are confirmed at quote time.