Siemens 3RW5554-2HA06 — Soft Starters

Siemens 3RW5554-2HA06 Soft Starter, 200-690V, ATEX, Active

MPN3RW5554-2HA06
Active

Siemens SIRIUS 3RW5554-2HA06 soft starter, 200-690 V rated voltage, ATEX/IECEx certified, trip class 10A/10E/20E/30E, Modbus TCP/RTU, EtherNet/IP, PROFIBUS, 478 x 764 x 241 mm (WxHxD).

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5554-2HA06 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5554-2HA06 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)450 kW
Rated motor power at 230 V (40 °C)250 kW
Rated operational current at 40 °C1 454 A
Rated operational current at 50 °C1 295 A
Rated operational current at 60 °C1 160 A
Rated insulation voltage690 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)12 187 W

Control & Connection

3RW5554-2HA06 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5554-2HA06 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes; Only up to 600 V operating voltage
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5554-2HA06 — Mechanical
ParameterValue
Height764 mm
Width478 mm
Depth241 mm
Weight45 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5554-2HA06 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude2 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5554-2HA06 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s

Electrical

3RW5554-2HA06 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and motor protection flexibility

The 3RW5554-2HA06: The trip class is configurable to CLASS 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. Class 10A/10E provides fast overload protection for standard-start motors, while Class 20E or 30E allows longer acceleration times for high-inertia loads like centrifuges or crushers. The default 10E setting suits most general-purpose motor starts, but the field-selectable range means one part covers both light and heavy starting duty without a hardware change.

Fieldbus and control integration

This soft starter supports Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS natively, with PROFIenergy available when paired with a PROFINET communication module. The analog output is configurable as 4-20 mA (default) or 0-10 V, feeding motor current or torque data to a PLC or SCADA. Torque control, voltage ramp, pump ramp down, and a breakaway pulse are built in — useful for soft-starting conveyors or pumps where mechanical shock must be minimized. DC braking is included for rapid stopping of high-inertia loads.

Mounting and environmental considerations

The unit measures 478 mm wide, 764 mm high, and 241 mm deep. Clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 0 mm backward, and 5 mm at the sides. The enclosure is designed for panel mounting — plan for adequate ventilation or forced cooling if the panel ambient exceeds 40 °C. Service factor is 1.15, allowing 15% continuous overload above rated motor current without tripping.

Diagnostics and maintainability

The soft starter includes an event list, error logbook, and trace function for fault analysis. Firmware updates are supported, and the unit is parameterizable with up to 4 parameter sets. Auto-reset and remote reset are available for unattended restart after a fault — useful for remote pumping stations or conveyor lines where manual reset is impractical. Accuracy class is 5 per IEC 61557-12, meaning measurement deviation stays within ±5% for current and voltage monitoring.

CE, UL, and CSA approvals are in place alongside ATEX and IECEx. The ATEX and IECEx marks confirm suitability for Zone 1/21 or Zone 2/22 hazardous areas, depending on the specific installation certificate. The unit also carries a motor heating function for anti-condensation protection during idle periods. Combined braking (DC injection + ramp) is available for faster, controlled stops.

Frequently asked questions

What is the trip class of 3RW5554-2HA06?

The trip class is field-selectable to CLASS 10A, 10E (default), 20E, or 30E per IEC 60947-4-2, covering standard and high-inertia motor starts.

Is Siemens 3RW5554-2HA06 ATEX certified?

Yes, it carries ATEX and IECEx certification for use in potentially explosive atmospheres.

Can 3RW5554-2HA06 be used with Modbus TCP?

Yes, it supports Modbus TCP natively, along with Modbus RTU, EtherNet/IP, and PROFIBUS.

What is the difference between 3RW5554-2HA06 and 3RW5554-2HA05?

The 3RW5554-2HA06 includes ATEX/IECEx certification and adds EtherNet/IP and PROFIenergy support compared to the 3RW5554-2HA05, which lacks these features. The 3RW5554-2HA05 is a functionally similar soft starter without hazardous-area approvals or certain fieldbus options.

MPN
3RW5554-2HA06