Siemens 3SF1324-1SG21-1BA1 — Safety Interlock Switches

Siemens 3SF1324-1SG21-1BA1 Safety Switch, 1300 N Locking, IP

MPN3SF1324-1SG21-1BA1
Active

Siemens SIRIUS 3SF1324-1SG21-1BA1 mechanical safety switch, tumbler design, 1300 N locking force, IP65/IP67, M12 fixed connector, ASIsafe integrated, positive opening.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3SF1324-1SG21-1BA1 — Identification
ParameterValue
Product designationMechanical safety switches
3SF1324-1SG21-1BA1 — Safety Function
ParameterValue
Switching functionpositive opening
Positive openingYes
Actuating element design5 directions of approach
3SF1324-1SG21-1BA1 — Electrical
ParameterValue
Electrical connection methodM12 plug, fixed
3SF1324-1SG21-1BA1 — Mechanical
ParameterValue
Mounting methodscrew fixing
Enclosure materialplastic
Housing designspecial design
3SF1324-1SG21-1BA1 — Environmental
ParameterValue
Ingress protection (IP rating)IP65/IP67
Operating temperature range-25 ... +60 °C
Storage temperature range-40 ... +80 °C

Product details

The Siemens SIRIUS 3SF1324-1SG21-1BA1 is a mechanical safety position switch with a tumbler mechanism and a separate actuator (3SE5000-0AV0, ordered separately). It integrates ASIsafe on a fixed M12 connector, carrying two safety channels: one NC for actuator monitoring and one NC for magnet monitoring, plus one NO per channel. The 1300 N locking force means the guard door stays positively latched under load — relevant for heavy or fast-moving access panels where a lower-force switch could be forced open. IP65/IP67 sealing lets it shrug off washdown spray on a bottling line or dust in a packaging area.

The 1300 N locking force exceeds the 1000 N minimum per EN ISO 14119, so it's rated for guarding applications where the interlock must resist forced opening. Positive opening per the switching function means the NC contacts are mechanically forced open when the actuator leaves the head — no spring reliance, which is the standard for safety circuits up to PL d / SIL 2. The ID1 code is set to F by default and can be configured across 0 through F, giving up to 16 addressable nodes on the AS-Interface bus. Repeat accuracy of 0.1 mm keeps the switch point consistent over a million operating cycles.

Deployment context

Mounts in any position via screw fixing onto machine frames or guard-door posts. The plastic enclosure with special design accepts actuation from five directions, which simplifies alignment on hinged or sliding guards. The M12 fixed connector with ASI+ on pin 1 and ASI- on pin 3 means a standard AS-Interface flat cable drop connects power and safety data in one run — no separate safety relay needed if the ASI master handles the safety monitor.

Frequently asked questions

What is the locking force of 3SF1324-1SG21-1BA1?

The locking force is 1300 N, which exceeds the 1000 N minimum required by EN ISO 14119. This means the switch positively latches the guard door against forced opening up to that force level.

What is the ID1 code on this safety switch?

The ID1 code is set to F by default and can be configured across the range 0 through F, allowing up to 16 addressable nodes on the AS-Interface bus.

Where can I buy 3SF1324-1SG21-1BA1 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

Does 3SF1324-1SG21-1BA1 have positive opening contacts?

Yes, the switching function is designed with positive opening, meaning the NC contacts are mechanically forced open when the actuator leaves the switch head. This is the standard for safety interlock circuits up to PL d / SIL 2.