Skip to main content
Siemens 3SF3200-6CV00-0BA1 — Safety Interlock Switches

Siemens 3SF3200-6CV00-0BA1 Position Switch, AS-i, IP65, 2NC

MPN3SF3200-6CV00-0BA1

Siemens SIRIUS 3SF3200-6CV00-0BA1 communication-capable position switch, mechanical plunger, AS-i insulation displacement connection, 2NC positive opening contacts, IP65 molded-plastic block housing per EN 50047.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3SF3200-6CV00-0BA1 — Identification
ParameterValue
Product designationcommunication-capable position switch
3SF3200-6CV00-0BA1 — Safety Function
ParameterValue
Operating principlemechanical
Switching functionpositive opening
Positive openingYes
Actuating element designrounded plunger
3SF3200-6CV00-0BA1 — Electrical
ParameterValue
Electrical connection methodAS-i insulation displacement method
3SF3200-6CV00-0BA1 — Contacts
ParameterValue
Auxiliary NC contacts2
Auxiliary NO contacts0
3SF3200-6CV00-0BA1 — Mechanical
ParameterValue
Mounting methodscrew fixing
Enclosure materialmolded-plastic
Housing designblock, EN 50047
3SF3200-6CV00-0BA1 — Environmental
ParameterValue
Ingress protection (IP rating)IP65
Operating temperature range-25 ... +60 °C

Product details

The Siemens 3SF3200-6CV00-0BA1 is a communication-capable position switch with an integrated AS-i adapter, built for direct connection to an AS-interface network without a separate I/O block. It uses a mechanical plunger actuator with positive opening contacts — meaning the NC contacts are mechanically forced open when the plunger is depressed, even if the contacts weld. That's a safety-circuit requirement per EN 60947-5-1, not just a reliability feature.

The switch body is a block design per EN 50047, molded-plastic, rated IP65. That's fine for washdown zones and dusty environments — it keeps coolant splash and airborne grit out of the contact chamber. The rounded plunger has a 6 mm diameter, so it works with standard cam profiles on linear or rotary actuators. Fastening is screw fixing; no DIN-rail clip here, so plan for direct panel or machine-frame mounting. Electrical connection is via AS-i insulation displacement method — you push the flat AS-i cable into the slot, and the contacts pierce the insulation. No stripping, no screw terminals on the network side. That saves wiring time but means the cable must be the correct flat profile; round cable won't work. The switch carries 2 NC auxiliary contacts and zero NO contacts, so it's a dedicated safety input — two-channel NC for a dual-channel safety circuit.

Frequently asked questions

What does the positive opening function mean on this switch?

Positive opening means the NC contacts are mechanically forced open when the plunger is actuated, even if the contacts have welded shut. This is a safety requirement per EN 60947-5-1, making the switch suitable for safety circuits like guard interlocking.

How is the AS-i connection made on this switch?

The switch uses the AS-i insulation displacement method — you press the flat AS-i cable into the slot, and internal contacts pierce the insulation. No stripping or screw terminals on the network side.

Where can I buy 3SF3200-6CV00-0BA1 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3SF3200-6CV00-0BA1