Siemens 3TK2826-1CW34 — Safety Relays

Siemens 3TK2826-1CW34

MPN3TK2826-1CW34

!!! Phased-out product!!! The successor product series is 3SK2 (see FAQ 109741483) SIRIUS safety relay with relay enabling circuits (EC) 24...240 V UC, 45 mm overall width screw terminal EC instantaneous: 2 NO EC delayed: 2 SC: 3 Switch with 8 functions Basic device Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3TK2826-1CW34 key specifications
ParameterValue
Type of electrical connectionscrew-type terminals
Safety device type according to IEC 61508-2Type B
Type of electrical connection Plug-In socketYes
Type of voltage of the control supply voltageAC/DC
Type of the Safety-Related wiring of the inputssingle-channel and two-channel
Insulation voltage rated value300 V
Surge voltage resistance rated value4 000 V
Thermal current of the switching element with contacts maximum5 A
Design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredgL/gG: 4 A, or quick: 6 A
Recovery time after power failure typical8.2 s
Operating frequency maximum2 000 1/h
Protection class IP of the enclosureIP20
3TK2826-1CW34 — By operating voltage
ParameterValue
At 24 V4 A
At 115 V3 A
At 230 V3 A
3TK2826-1CW34 — By frequency
ParameterValue
At 50 Hz0.9 ... 1.1
At 60 Hz0.9 ... 1.1

All specifications

3TK2826-1CW34 additional specifications
ParameterValue
Mounting positionany
Installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
Installation altitude at height above sea level maximum2 000 m
DC resistance of the cable maximum1 000 Ω
Protection class IP of the terminalIP20
Shock resistance8g / 10 ms
EMC emitted interferenceEN 60947-5-1
Relative humidity during operation10 ... 95 %
Touch protection against electrical shockfinger-safe
Vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0,075 mm
Depth120 mm
Width45 mm
Height138.5 mm
UL approvalYes
BG BIA approvalYes
According to IEC 615083
Hardware fault tolerance according to IEC 615081
For delayed release circuit according to IEC 61508SIL3
Solid2x (20 ... 14)
At DC0.9 ... 1.1
Typical50 ms
Stranded2x (20 ... 14)
Start inputYes
1 rated value50 Hz
2 rated value60 Hz
Safety switchYes
At AC maximum100 ms
At DC maximum100 ms
During storage-40 ... +80 °C
Feedback inputYes
Automatic startYes
During operation-25 ... +60 °C
Mountingscrew and snap-on mounting
Valve monitoringNo
Delayed switching0
Monitored Start-UpYes
Design of the productfor EMERGENCY-STOP and safety doors
Instantaneous contact0
Standstill monitoringNo
1-Channel or 2-Channel1
EMERGENCY OFF functionYes
Light array monitoringYes
Design of the cascadingcascading or in-service switching
Safety-Related circuitsYes
Laser scanner monitoringYes
Light barrier monitoringYes
With core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Rotation speed monitoringNo
Tactile sensor monitoringYes
Position switch monitoringYes
Protective door monitoringYes
Of the sensor input minimum30 ms
Monitoring of floating sensorsYes
Of the cascading input minimum0.2 s
EMERGENCY-OFF circuit monitoringYes
Safety-Related delayed switching2
Pressure-Sensitive mat monitoringYes
Monitoring of Non-Floating sensorsYes
Air pressure according to SN 3120590 ... 106 kPa
Of the ON pushbutton input minimum0.2 s
Product feature Cross-Circuit-ProofYes
Cascading input (Functional switching)Yes
Safety-Related instantaneous contact2
Category according to EN ISO 13849-14
Stop category according to EN 60204-10 + 1
Reference code according to EN 61346-2F
Magnetically operated switch monitoringYes
For signaling function delayed switching1
Suitability for interaction press controlNo
For signaling function instantaneous contact2
Magnetically operated switch monitoring NC-NCYes
Magnetically operated switch monitoring NC-NOYes
Electrical endurance (Operating cycles) typical100 000
PFHD with high demand rate according to EN 620617.8E-9 1/h
SIL claim limit (subsystem) according to EN 620613
Mechanical service life (Operating cycles) typical10 000 000
MPN
3TK2826-1CW34