Skip to main content
Siemens 3TK2827-1AJ21 — Safety Relays

Siemens 3TK2827-1AJ21

MPN3TK2827-1AJ21

SIRIUS safety relay with relay enabling circuits (EC) 115 V AC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 2NO, 0.05...3 s SC: 1NC monitored start Basic device Maximum achieved SIL: 3/2, PL: e/d

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3TK2827-1AJ21 key specifications
ParameterValue
Type of electrical connectionscrew-type terminals
Safety device type according to IEC 61508-2Type A
Type of electrical connection Plug-In socketYes
Type of voltage of the control supply voltageAC
Type of the Safety-Related wiring of the inputssingle-channel and two-channel
Insulation voltage rated value300 V
Surge voltage resistance rated value4 000 V
Thermal current of the switching element with contacts maximum5 A
Design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredgL/gG: 6 A, or quick: 10 A
Recovery time after power failure typical200 ms
Operating frequency maximum1 000 1/h
At ac-15 at 2305 A
3TK2827-1AJ21 — By frequency
ParameterValue
At 50 Hz0.85 ... 1.1
At 60 Hz0.85 ... 1.1
At 50 Hz rated value115 V
At 60 Hz rated value115 V

All specifications

3TK2827-1AJ21 additional specifications
ParameterValue
Protection class IP of the enclosureIP20
Mounting positionany
Installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
Installation altitude at height above sea level maximum2 000 m
DC resistance of the cable maximum30 Ω
Protection class IP of the terminalIP20
Shock resistance8g / 10 ms
EMC emitted interferenceEN 60947-5-1
Relative humidity during operation10 ... 95 %
Touch protection against electrical shockfinger-safe
Vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0,075 mm
Depth120 mm
Width44.8 mm
Height138.5 mm
UL approvalYes
BG BIA approvalYes
According to IEC 615083
Hardware fault tolerance according to IEC 615081
For delayed release circuit according to IEC 61508SIL2
Solid2x (20 ... 14)
At DC0.85 ... 1.1
Typical8 000 ms
Stranded2x (20 ... 14)
Start inputYes
1 rated value50 Hz
2 rated value60 Hz
Safety switchYes
During storage-40 ... +80 °C
Feedback inputYes
Automatic startNo
During operation-25 ... +60 °C
Mountingscrew and snap-on mounting
Valve monitoringNo
At dc-13 at 245 A
Delayed switching0
Monitored Start-UpYes
Design of the productfor EMERGENCY-STOP and safety doors
Instantaneous contact0
Standstill monitoringNo
1-Channel or 2-Channel1
EMERGENCY OFF functionYes
Light array monitoringNo
Safety-Related circuitsYes
Laser scanner monitoringNo
Light barrier monitoringNo
With core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Rotation speed monitoringNo
Tactile sensor monitoringNo
Position switch monitoringYes
Protective door monitoringNo
Of the sensor input minimum25 ms
Monitoring of floating sensorsYes
EMERGENCY-OFF circuit monitoringYes
Safety-Related delayed switching2
Pressure-Sensitive mat monitoringYes
Monitoring of Non-Floating sensorsNo
Air pressure according to SN 3120590 ... 106 kPa
Of the ON pushbutton input minimum0.025 s
Product feature Cross-Circuit-ProofYes
Cascading input (Functional switching)No
Safety-Related instantaneous contact2
Category according to EN ISO 13849-14
Stop category according to EN 60204-10 + 1
Reference code according to EN 61346-2F
Magnetically operated switch monitoringNo
Suitability for interaction press controlNo
For signaling function instantaneous contact1
Magnetically operated switch monitoring NC-NCNo
Magnetically operated switch monitoring NC-NONo
Electrical endurance (Operating cycles) typical100 000
PFHD with high demand rate according to EN 620612.7E-9 1/h
SIL claim limit (subsystem) according to EN 620613
Mechanical service life (Operating cycles) typical10 000 000
MPN