Siemens 3TK2853-2BB40-0AB1
MPN3TK2853-2BB40-0AB1
!!! Phased-out product!!! SIGUARD safety combination Electronic basic unit STOP-0, Maximum achieved SIL:3, PL:E STOP-0, 6 EC, 1 HL Signaling circuit, 1NC Spring-type terminal 24 V DC Customer type (KRAUSS-MAFFEI) Width 90 mm
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Type of electrical connection | spring-loaded terminals |
| Safety device type according to IEC 61508-2 | Type B |
| Type of voltage of the control supply voltage | DC |
| Insulation voltage rated value | 690 V |
| Surge voltage resistance rated value | 6 000 V |
| Design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required | gL/gG: 10 A |
| Recovery time after power failure typical | 7 s |
| Operating frequency maximum | 1 000 1/h |
| Protection class IP of the enclosure | IP20 |
| Mounting position | any |
| Installation altitude at height above sea level maximum | 2 000 m |
| DC resistance of the cable maximum | 500 Ω |
| Parameter | Value |
|---|---|
| At 24 V | 10 A |
| At 115 V | 6 A |
| At 230 V | 6 A |
All specifications
| Parameter | Value |
|---|---|
| Protection class IP of the terminal | IP20 |
| Shock resistance | 5g / 11 ms |
| EMC emitted interference | IEC 60947-5-1, IEC 60000-4-3, IEC 60000-4-5, IEC 60000-4-6 |
| Relative humidity during operation | 10 ... 95 % |
| Touch protection against electrical shock | finger-safe |
| Vibration resistance according to IEC 60068-2-6 | 5 ... 500 Hz: 0,075 mm |
| UL approval | Yes |
| BG BIA approval | Yes |
| According to IEC 61508 | 3 |
| Hardware fault tolerance according to IEC 61508 | 1 |
| Solid | 1x (24 ... 18) |
| At DC | 0.85 ... 1.1 |
| Typical | 120 ms |
| Stranded | 1x (24 ... 18) |
| Safety switch | Yes |
| At DC maximum | 100 ms |
| During storage | -40 ... +80 °C |
| During operation | -25 ... +60 °C |
| Valve monitoring | No |
| At DC rated value | 24 V |
| 1-Channel or 2-Channel | 1 |
| Safety-Related circuits | Yes |
| Tactile sensor monitoring | Yes |
| Position switch monitoring | Yes |
| Of the sensor input minimum | 45 ms |
| Without core end processing | 1x (0.25 ... 1.5 mm²) |
| Monitoring of floating sensors | Yes |
| Of the cascading input minimum | 0.045 s |
| EMERGENCY-OFF circuit monitoring | Yes |
| Monitoring of Non-Floating sensors | Yes |
| Air pressure according to SN 31205 | 90 ... 106 kPa |
| Of the ON pushbutton input minimum | 0.2 s |
| Category according to EN ISO 13849-1 | 4 |
| Stop category according to EN 60204-1 | 0 |
| Magnetically operated switch monitoring | No |
| Contact reliability of auxiliary contacts | < 1 error per 100 million operating cycles |
| PFHD with high demand rate according to EN 62061 | 1.1E-8 1/h |
| Mechanical service life (Operating cycles) typical | 30 000 000 |
| Recovery time after opening of the safety circuits typical | 500 ms |
| Backslide delay time after opening of the safety circuits typical | 50 ms |
MPN
3TK2853-2BB40-0AB1