Skip to main content
Siemens 3TK2853-2BB40-0AB1 — Safety Relays

Siemens 3TK2853-2BB40-0AB1

MPN3TK2853-2BB40-0AB1

!!! Phased-out product!!! SIGUARD safety combination Electronic basic unit STOP-0, Maximum achieved SIL:3, PL:E STOP-0, 6 EC, 1 HL Signaling circuit, 1NC Spring-type terminal 24 V DC Customer type (KRAUSS-MAFFEI) Width 90 mm

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3TK2853-2BB40-0AB1 key specifications
ParameterValue
Type of electrical connectionspring-loaded terminals
Safety device type according to IEC 61508-2Type B
Type of voltage of the control supply voltageDC
Insulation voltage rated value690 V
Surge voltage resistance rated value6 000 V
Design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredgL/gG: 10 A
Recovery time after power failure typical7 s
Operating frequency maximum1 000 1/h
Protection class IP of the enclosureIP20
Mounting positionany
Installation altitude at height above sea level maximum2 000 m
DC resistance of the cable maximum500 Ω
3TK2853-2BB40-0AB1 — By operating voltage
ParameterValue
At 24 V10 A
At 115 V6 A
At 230 V6 A

All specifications

3TK2853-2BB40-0AB1 additional specifications
ParameterValue
Protection class IP of the terminalIP20
Shock resistance5g / 11 ms
EMC emitted interferenceIEC 60947-5-1, IEC 60000-4-3, IEC 60000-4-5, IEC 60000-4-6
Relative humidity during operation10 ... 95 %
Touch protection against electrical shockfinger-safe
Vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0,075 mm
UL approvalYes
BG BIA approvalYes
According to IEC 615083
Hardware fault tolerance according to IEC 615081
Solid1x (24 ... 18)
At DC0.85 ... 1.1
Typical120 ms
Stranded1x (24 ... 18)
Safety switchYes
At DC maximum100 ms
During storage-40 ... +80 °C
During operation-25 ... +60 °C
Valve monitoringNo
At DC rated value24 V
1-Channel or 2-Channel1
Safety-Related circuitsYes
Tactile sensor monitoringYes
Position switch monitoringYes
Of the sensor input minimum45 ms
Without core end processing1x (0.25 ... 1.5 mm²)
Monitoring of floating sensorsYes
Of the cascading input minimum0.045 s
EMERGENCY-OFF circuit monitoringYes
Monitoring of Non-Floating sensorsYes
Air pressure according to SN 3120590 ... 106 kPa
Of the ON pushbutton input minimum0.2 s
Category according to EN ISO 13849-14
Stop category according to EN 60204-10
Magnetically operated switch monitoringNo
Contact reliability of auxiliary contacts< 1 error per 100 million operating cycles
PFHD with high demand rate according to EN 620611.1E-8 1/h
Mechanical service life (Operating cycles) typical30 000 000
Recovery time after opening of the safety circuits typical500 ms
Backslide delay time after opening of the safety circuits typical50 ms
MPN