Siemens SIRIUS active power monitoring relay, 3UG3014-1BP60, rated 340-460 V AC, 0.2-10 A measurable current, IP20, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3UG3014-1BP60 — Identification
ParameterValue
Product functionActive power monitoring relay
Product line / brand nameSIRIUS
3UG3014-1BP60 — Electrical
ParameterValue
Rated value (50 Hz)340 ... 460 V
Rated value (60 Hz)340 ... 460 V
3UG3014-1BP60 — Communication
ParameterValue
Electrical connection typescrew-type terminals
3UG3014-1BP60 — Environmental
ParameterValue
Ingress protection (IP rating), wiredIP20
3UG3014-1BP60 — Mechanical
ParameterValue
Mounting typesnap-on mounting
Width45 mm
Height100 mm
Depth100 mm
Conductor cross-section, solid20 ... 14
Conductor cross-section, finely stranded (with ferrule)0.5 ... 2.5 mm²
Mounting clearance, top0 mm
Mounting clearance, rear0 mm
Mounting clearance, side0 mm
Mounting clearance, front0 mm

Product details

The Siemens 3UG3014-1BP60 is a SIRIUS active power monitoring relay — it watches real power consumption on a motor or load and trips an internal relay when the power goes outside a set window. That makes it useful for detecting a broken belt, a jammed conveyor, a dry-running pump, or a load that's drifted off its normal draw. The relay measures current from 0.2 A up to 10 A and accepts a supply voltage of 340-460 V AC at both 50 Hz and 60 Hz. The trip delay is adjustable: 0.3-3 s on startup to ride through inrush, and 0.5-20 s on an upper or lower limit violation to ignore short transients. Two changeover contacts (delayed switching) handle the output, rated 3 A at 250 V AC or 400 V AC, 50/60 Hz. For DC loads, the contacts are rated 1 A at 24 V, 0.2 A at 125 V, and 0.1 A at 250 V.

IP20 finger-safe housing. Tightening torque 1.2-0.8 N·m. Zero clearance needed above, below, forward, backward, or to the side — the relay can be butted against other devices without derating.

Vibration tested per IEC 60068-2-6: 1-6 Hz at 15 mm amplitude, 6-500 Hz at 2 g. Shock tested per IEC 60068-2-27: 15 g / 11 ms half-sine. Surge voltage resistance rated 6 kV. Repeat accuracy of the power measurement is 1 %; metering precision is 10 %.

Frequently asked questions

What are the key ratings for this relay?

Supply voltage 340-460 V AC, measurable current 0.2-10 A, output contacts rated 3 A at 250/400 V AC. Adjustable start-up delay 0.3-3 s and limit violation delay 0.5-20 s.

MPN