Siemens 3UG3082-1AW30 — Process / Temperature Controllers

Siemens 3UG3082-1AW30 SIRIUS Insulation Monitor, 110–400 V A

MPN3UG3082-1AW30

Siemens SIRIUS 3UG3082-1AW30 insulation monitor, for ungrounded DC IT networks, measuring range 10 to 110 kΩ, supply AC/DC 24–240 V, 1 CO contact, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3UG3082-1AW30 — Identification
ParameterValue
Product functionInsulation monitor
Product line / brand nameSIRIUS
3UG3082-1AW30 — Electrical
ParameterValue
Rated value (50 Hz)24 ... 240 V
Rated value (60 Hz)24 ... 240 V
3UG3082-1AW30 — Communication
ParameterValue
Electrical connection typescrew-type terminals
3UG3082-1AW30 — Environmental
ParameterValue
Ingress protection (IP rating), wiredIP20
3UG3082-1AW30 — Mechanical
ParameterValue
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail
Mounting positionany
Width45 mm
Height100 mm
Depth100 mm
Conductor cross-section, solid0.75 ... 2.5 mm²
Conductor cross-section, finely stranded (with ferrule)0.75 ... 2.5 mm²
Mounting clearance, top0 mm
Mounting clearance, rear0 mm
Mounting clearance, side0 mm
Mounting clearance, front0 mm

Product details

The Siemens 3UG3082-1AW30 is a SIRIUS insulation monitor designed for ungrounded DC IT networks, measuring insulation resistance in the range of 10 to 110 kΩ. It operates from a control supply voltage of AC/DC 24–240 V (50/60 Hz) and also accepts a rated value of 110–400 V AC/DC, making it flexible for different panel voltages.

The 10–110 kΩ measurement range covers the typical insulation resistance window for ungrounded DC systems (IT networks) in industrial control panels, motor drives, and solar arrays. A reading below 10 kΩ indicates a serious ground fault; above 110 kΩ the insulation is healthy. The device stores the fault (fault storage = Yes) and has a configurable switching delay (delayed switching = 1), so it can ignore transient leakage spikes that would otherwise cause nuisance trips — useful on lines with capacitive coupling or intermittent loads. Supply flexibility is a strong point: the control supply accepts AC/DC 24–240 V at 50/60 Hz, while the monitored circuit can be at 110–400 V AC/DC. That means the same monitor can be wired into a 24 VDC control panel or a 230 VAC distribution board without a separate power supply module — a real time-saver during panel build.

Screw terminals require a tightening torque of 0.5–0.8 N·m. The removable terminal for auxiliary and control circuits is not provided (No), so the unit is wired directly in the panel. Zero clearance required on all sides (upwards, forwards, backwards, downwards, at the side all 0 mm), meaning it can be mounted flush against other components without derating.

Frequently asked questions

What is the supply voltage range for this insulation monitor?

The control supply voltage accepts AC/DC 24–240 V at 50/60 Hz. Additionally, the rated value for the monitored circuit is 110–400 V AC/DC. This allows direct connection to a wide range of panel voltages without an external power supply.

What wire sizes and terminal type does it accept?

Screw-type terminals accept solid or finely stranded wire with core end processing from 0.75 to 2.5 mm². Tightening torque is 0.5–0.8 N·m.

Does it have fault storage and a delay function?

Yes, fault storage is enabled (Yes) and the device has a configurable switching delay (delayed switching = 1). This allows it to latch a fault indication and ignore brief leakage transients.

MPN
3UG3082-1AW30