Skip to main content
Siemens 3UG4622-1AA30 — Process / Temperature Controllers

Siemens 3UG4622-1AA30 SIRIUS Current Monitoring Relay, 0.05-

MPN3UG4622-1AA30
NRND

Siemens SIRIUS 3UG4622-1AA30, current monitoring relay with digital setting, measuring range 0.05 … 10 A, 22.5 mm width, IP20, snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3UG4622-1AA30 — Identification
ParameterValue
Product functionCurrent monitoring relay
Product designationCurrent monitoring relay with digital setting
Product line / brand nameSIRIUS
3UG4622-1AA30 — Electrical
ParameterValue
Rated value (50 Hz)24 V
Rated value (60 Hz)24 V
3UG4622-1AA30 — Environmental
ParameterValue
Ingress protection (IP rating), wiredIP20
Installation altitude, max.2 000 m
3UG4622-1AA30 — Mechanical
ParameterValue
Fastening methodsnap-on mounting
Mounting positionany
Width22.5 mm
Height92 mm
Depth91 mm
Conductor cross-section, solid20 ... 14
Conductor cross-section, finely stranded (with ferrule)0.5 ... 2.5 mm²
Mounting clearance, top0 mm
Mounting clearance, rear0 mm
Mounting clearance, side0 mm
Mounting clearance, front0 mm

Product details

The 3UG4622-1AA30: Supply voltage is 24 V DC nominal (20.4–26.4 V), with a contact rated 3 A at 250 V AC for switching alarm or control circuits.

The headline measuring range of 0.05 … 10 A is what you set via the digital interface; the relay can actually measure up to 15 A, giving headroom for brief overloads or a wider motor FLA without swapping the unit. Contact rating of 3 A at 250 V AC means it drives a contactor coil or a PLC input directly; at 24 V DC the same contact is rated 1 A. The auto-reset and external reset options let you choose between latching and automatic restart — handy for remote restart of a pump or conveyor.

Terminals accept 20–14 AWG solid or stranded, with 2× conductor capacity for looping through. Depth is 91 mm, height 92 mm — leaves room for wiring ducts in a standard 120 mm deep enclosure.

Frequently asked questions

What is the measuring range of the 3UG4622-1AA30?

The adjustable monitoring range is 0.05 … 10 A, and the relay can measure up to 15 A for applications needing a wider span.

What supply voltage does the 3UG4622-1AA30 need?

It requires 24 V DC nominal, with an operating range of 20.4 … 26.4 V.

What is the contact rating of the 3UG4622-1AA30?

The output relay is rated 3 A at 250 V AC, 1 A at 24 V DC, and 0.1 A at 250 V DC.

MPN
3UG4622-1AA30