Siemens 3UG5462-1AA40 SIRIUS DC Load Monitoring Relay, PROFI

MPN3UG5462-1AA40
NRND

Siemens SIRIUS DC load monitoring relay, 3UG5462-1AA40, PROFINET IO, -63 … +63 A, 0 … 800 V DC, 45 mm width, screw and snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3UG5462-1AA40 — Identification
ParameterValue
Product functionDC load monitoring relay
Product designationDC load monitoring relay
Product line / brand nameSIRIUS
3UG5462-1AA40 — Communication
ParameterValue
Electrical connection typescrew-type terminals
3UG5462-1AA40 — Environmental
ParameterValue
Installation altitude, max.2 000 m
3UG5462-1AA40 — Mechanical
ParameterValue
Fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Mounting positionany
Width45 mm
Height100 mm
Depth141.6 mm
Conductor cross-section, solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded (with ferrule)2x (0,5 ... 1,5 mm²), 1x (0,5 ... 4 mm²)
Mounting clearance, top50 mm
Mounting clearance, rear0 mm
Mounting clearance, side3 mm
Mounting clearance, front0 mm

Product details

The 3UG5462-1AA40: The -63 to +63 A measurable current range covers bidirectional DC loads — motor drives, battery banks, or DC bus monitoring — where current can flow in either direction. The 0 to 800 V adjustable voltage range matches common DC link voltages in industrial drives and solar arrays. The 100 ms response time is fast enough to catch short-duration faults without nuisance tripping on inrush. The auxiliary contact is rated 0.5 A at 125 V AC resistive load up to 40 °C, suitable for signaling to a PLC input or contactor coil. At 24 V DC the contact carries 1 A. The relay consumes a maximum of 3 W, which is low enough to avoid thermal concerns in a crowded DIN-rail cabinet. Galvanic isolation between input and output means the monitoring circuit is electrically separate from the PROFINET communication and auxiliary contacts — important for avoiding ground loops in mixed AC/DC panels.

The front face is IP20, terminals are IP00 — standard for inside a control cabinet. Clearance distances: 50 mm above and below, 3 mm at the sides, 0 mm forward and backward. This is tight for side-by-side DIN-rail mounting but allows stacking with minimal gap.

EMC compliance is per IEC 60947-1 and IEC 61000-6-2 / IEC 61000-6-4, covering industrial immunity and emission limits. The PROFINET IO implementation conforms to Conformance Class A, ensuring interoperability with standard PROFINET controllers.

Frequently asked questions

What is the measurable current range of the 3UG5462-1AA40?

It measures DC currents from -63 to +63 A, covering bidirectional flow. The adjustable voltage range is 0 to 800 V DC.

What is the auxiliary contact rating?

The auxiliary contact is rated 0.5 A at 125 V AC resistive load up to 40 °C, and 1 A at 24 V DC.

Does the 3UG5462-1AA40 support PROFINET?

Yes, it has PROFINET IO protocol with Conformance Class A, suitable for integration into standard PROFINET networks.

What compliance documentation is available for this relay?

The relay complies with IEC 60947-1 and IEC 61000-6-2 / IEC 61000-6-4 for EMC. Standard Siemens documentation includes RoHS and REACH declarations; specific certificates can be provided upon request through the authorized channel.