Siemens 3UG5816-2AA40 — Process / Temperature Controllers

Siemens 3UG5816-2AA40 Line Monitoring Relay, 90-690 V AC, IO

MPN3UG5816-2AA40
Active

Siemens SIRIUS 3UG5816-2AA40, digitally adjustable monitoring relay, phase failure/sequence/asymmetry/frequency/overvoltage/undervoltage, 90-690 V AC, 15-70 Hz, 1 changeover contact, spring-loaded terminal, IO-Link.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3UG5816-2AA40 — Identification
ParameterValue
Product familyLine monitoring
3UG5816-2AA40 — Approvals
ParameterValue
RoHS complianceSince: 01-06-23
REACH Art. 33 (SVHC disclosure)Lead CAS-No. 7439-92-1 > 0,1 % (w / w)
3UG5816-2AA40 — Other specifications
ParameterValue
Group codeR711
Product group5885
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Export control regulationsAL : N / ECCN : N

Product details

The Siemens 3UG5816-2AA40 is a digitally adjustable monitoring relay from the SIRIUS line monitoring family, covering phase failure, phase sequence, asymmetry, frequency, overvoltage, and undervoltage on three-phase systems with or without a neutral conductor. It operates across 90-690 V AC at 15-70 Hz, making it suitable for 50/60 Hz networks worldwide. The single changeover contact is rated for general-purpose switching, and the spring-loaded terminals accept 0.2-2.5 mm² conductors — no screwdriver needed for termination. IO-Link connectivity gives the PLC direct access to the measured values and device diagnostics, which saves a panel scan for a separate analog input.

The 90-690 V AC input range covers low-voltage networks from 110 V to 690 V line-to-line without needing a separate voltage tap. Phase asymmetry detection triggers when the voltage imbalance exceeds the adjustable threshold — typically set at 5-10 % to catch a failing motor winding or a loose connection before the motor overheats. The single changeover contact (SPDT) is enough to drive a PLC digital input or a contactor coil; if you need two isolated signals, you will need an auxiliary relay block.

Integration notes

The packaging dimensions (127 x 111 x 38 mm) give you the footprint for panel layout — it occupies roughly 4 module widths on the rail. IO-Link communication uses the standard M12 connector (not included); set the IO-Link address via the master or the onboard DIP switches. The relay's self-test and measured-value output can be polled cyclically, which eliminates the need for a separate analog input module for voltage monitoring.

Frequently asked questions

What are the key ratings for the 3UG5816-2AA40?

Supply voltage 90-690 V AC, frequency range 15-70 Hz, one changeover contact (SPDT) with spring-loaded terminals. IO-Link capable for direct PLC communication of measured values and diagnostics.