Skip to main content
Siemens 3VA1010-2ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED32-0AA0 SENTRON MCCB, 100 A, 3-Pole, TM21

MPN3VA1010-2ED32-0AA0
Active

Siemens SENTRON 3VA1010-2ED32-0AA0, 3-pole molded case circuit breaker, 100 A rated continuous current, TM210 thermal-magnetic release, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1010-2ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1010-2ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.25 W
3VA1010-2ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-2ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1010-2ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1010-2ED32-0AA0 — 100 A MCCB, Line Protection, TM210 Release

Its interrupting capacity reaches 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V — so at typical 400 V class distribution voltages, it handles fault currents up to 32 kA, which covers most secondary distribution panels. Thermal derating is minimal up to 50 °C — it holds full 100 A — then drops to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C.

Dimensions are 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that drops into most Siemens SENTRON distribution panels and switchboard chassis without modification. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C — fine for most indoor industrial environments, but the upper operating limit matches the derating curve's endpoint, so don't expect full 100 A above 70 °C.

For BOM freeze or PCN watch, the 3VA platform is Siemens' mainstream MCCB line, so replacements and upgrades tend to follow the same physical footprint and accessory ecosystem.

If you need those features, you'd look at the 3VA1 with the appropriate suffix.

Frequently asked questions

What does the TM210 release designation mean?

TM210 means a thermal-magnetic release with a 100 A fixed thermal element (the '100' in the code) and an adjustable magnetic short-circuit pickup — standard for feeder protection where you set the magnetic threshold above motor inrush.

MPN
3VA1010-2ED32-0AA0