Skip to main content
Siemens 3VA1010-2ED32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED32-0DA0 SENTRON MCCB, 100 A, 52.5 kA

MPN3VA1010-2ED32-0DA0

Siemens SENTRON 3VA1010-2ED32-0DA0, 3-pole molded case circuit breaker, 100 A, line protection with TM210 thermal-magnetic trip unit and undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-2ED32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA10102ED320AA0
3VA1010-2ED32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.27.5 W
3VA1010-2ED32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1010-2ED32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1010-2ED32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED32-0DA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It carries a 52.5 kA interrupting capacity at 240 V, derating to 32 kA at 415 V and 13.6 kA at 440 V.

Rated 100 A from 40 °C through 50 °C; at 55 °C it drops to 98 A, at 60 °C to 96 A, and at 70 °C to 91 A. That means in a sealed panel with a 60 °C internal ambient the breaker still delivers 96 A — no need to oversize for a warm cabinet. Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep, fitting the standard DIN-rail footprint for a 3-pole MCCB.

Trip unit and auxiliary release

The TM210 overcurrent release is a fixed thermal-magnetic type — no interchangeable rating plugs, so the 100 A frame is the breaker you get. Rated insulation voltage is 800 V, operating range -25 °C to 70 °C, storage from -40 °C to 80 °C.

Frequently asked questions

What is 3VA1010-2ED32-0DA0 used for?

It is a 3-pole molded case circuit breaker for line protection in industrial distribution panels, rated 100 A with a TM210 thermal-magnetic trip unit and an undervoltage release.

What are the interrupting ratings for 3VA1010-2ED32-0DA0?

52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

What is the closest alternative to 3VA1010-2ED32-0DA0?

The 3VA1010-2ED32-0DC0 is the same 100 A frame and TM210 trip unit but without the undervoltage release. It drops into the same panel footprint and power wiring; only the control circuit differs.

Where can I buy 3VA1010-2ED32-0DA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3VA1010-2ED32-0DA0