Siemens 3VA1010-2ED32-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED32-0HA0 Circuit Breaker, 100 A, 16 kA

MPN3VA1010-2ED32-0HA0

Siemens 3VA1 IEC Frame 100, circuit breaker, 3-pole, 100 A, switching capacity class B, Icu=16 kA @ 415 V, system protection TM210, FTFM, shunt release (STL) 12-30 V DC / 24 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1010-2ED32-0HA0 is a 3-pole IEC Frame 100 circuit breaker rated 100 A with a switching capacity class B interrupting capacity of 16 kA at 415 V. It is configured for system protection with a TM210 thermal-magnetic trip unit — fixed overload protection at Ir=100 A and fixed short-circuit protection at Ii = 10 × In (1000 A). This is a DIN-rail-mounting breaker sized for distribution panels and sub-distribution boards where the 16 kA SCCR at 415 V is sufficient for the fault level at the point of installation. The lug terminals accept standard copper conductors; no adapter kit needed for panel wiring.

For a panel with a prospective fault current above 16 kA at the breaker's location, you would need a higher-capacity frame (class C or higher) or upstream current-limiting fuses to coordinate. The fixed Ir=100 A means this breaker is not field-adjustable for overload pickup — it is a dedicated 100 A thermal-magnetic unit. If the connected load draws less than 100 A continuously, the breaker still protects at its fixed rating; if the load is expected to exceed 100 A, select a higher-rated frame. The fixed Ii=1000 A (10 × In) short-circuit pickup is suitable for motor circuits where the inrush may reach 6-8× FLA, but verify coordination with downstream branch devices. The shunt release coil draws power only during the trip command — it is not continuously energized. The 12-30 V DC / 24 V AC control voltage range covers common industrial control voltages; verify the control transformer or DC supply matches the coil rating before wiring.

Frequently asked questions

What is the interrupting capacity of this breaker?

The interrupting capacity Icu is 16 kA at 415 V AC, switching capacity class B per IEC 60947-2.

How do I get pricing and availability for 3VA1010-2ED32-0HA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the closest alternative to this breaker in the same family?

Within the 3VA1 frame, the closest variant would differ by trip unit type (adjustable thermal vs fixed), shunt release voltage, or terminal style (box lug vs ring lug). No pin-compatible direct drop-in exists with identical fixed settings — verify the trip curve and accessory voltage before substituting.