Skip to main content
Siemens 3VA1010-2ED32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED32-0JC0 SENTRON MCCB, 100 A, 52.5 kA

MPN3VA1010-2ED32-0JC0

Siemens SENTRON 3VA1010-2ED32-0JC0, molded case circuit breaker, 3-pole, 100 A, TM210 thermal-magnetic release, 52.5 kA at 240 V, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-2ED32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-2ED32-0JC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1010-2ED32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1010-2ED32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1010-2ED32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED32-0JC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1010-2ED32-0JC0 is a 3-pole molded case circuit breaker rated for 100 A continuous at 40 °C, with the TM210 thermal-magnetic release handling overload and short-circuit protection in a single device. That 100 A holds flat through 50 °C — only starts tapering at 55 °C (96 A), hitting 90 A at 70 °C, so in a warm panel you still have headroom. Breaking capacity runs 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — enough for most industrial distribution boards on the secondary side of a 500 kVA transformer. It ships with a factory-fitted shunt trip (STL) release (order code 3VA9688-0BL32 for the integrated auxiliary trip assembly) and two HQ auxiliary switches, so you get remote tripping and status feedback without adding an external module.

The 3VA1010-2ED32-0JC0 measures 130 mm high, 76.2 mm wide (standard 3-pole MCCB footprint), and 70 mm deep — fits a 200 mm deep enclosure with room for rear-mounted busbars or a DIN-rail adapter. Spring-cage terminals on the line and load sides accept copper conductors up to the rated cross-section for 100 A; torque to the values stamped on the device nameplate.

Frequently asked questions

How do I get pricing and availability for 3VA1010-2ED32-0JC0?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is the closest functional alternative to 3VA1010-2ED32-0JC0?

The 3VA1010-2ED32-0JA0 is the same 100 A, 3-pole, TM210 MCCB but without the factory-fitted shunt trip and auxiliary switches. If you need remote tripping and status feedback, the -0JC0 variant saves panel wiring labor versus adding those accessories later.

What are the key ratings for 3VA1010-2ED32-0JC0?

Rated continuous current 100 A (flat to 50 °C, derated above). Breaking capacity 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, 7.5 kA at 690 V. Rated insulation voltage 800 V. TM210 thermal-magnetic release with shunt trip and 2 HQ auxiliary switches.

What compliance documentation does Siemens provide for this MCCB?

The SENTRON 3VA series carries IEC 60947-2 certification for molded case circuit breakers. Siemens provides a declaration of conformity and, on request, the full test report. RoHS and REACH compliance declarations are available through the Siemens Industry Online Support portal.

MPN