Skip to main content
Siemens 3VA1010-2ED42-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED42-0KC0 SENTRON MCCB, 100 A, 4-Pole, 52.5

MPN3VA1010-2ED42-0KC0

Siemens SENTRON 3VA1010-2ED42-0KC0, molded case circuit breaker, 4-pole, 100 A, TM210 overcurrent release, 52.5 kA at 240 V, 32 kA at 415 V, shunt trip, 2 HQ auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-2ED42-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-2ED42-0KC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1010-2ED42-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1010-2ED42-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED42-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1010-2ED42-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED42-0KC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens 3VA1010-2ED42-0KC0 is a SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C through 50 °C, with a TM210 thermal-magnetic overcurrent release. The interrupting ratings tell the real story: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V — so it handles high-fault-capacity service entrances and downstream sub-distribution without cascading upstream. The shunt trip is wired separately to a control voltage — useful for remote emergency-off or supervisory tripping. No trip indicator on the front means you rely on the auxiliary contacts or a separate indication relay to know the breaker state after a trip. Panel integration: the 101.6 mm width (4-inch standard) and 130 mm height fit Siemens 3VA fixed-pattern mounting plates and common DIN-rail adapters. The 70 mm depth leaves room for rear-connected busbars or cable ladders.

Thermal derating — the number that governs real use

Above that, it derates: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. If your panel ambient runs at 60 °C — common in a packed enclosure near a furnace or drive cabinet — the breaker is effectively a 94 A device.

Frequently asked questions

Where can I buy 3VA1010-2ED42-0KC0 and what is the lead time?

This MCCB is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — lead time is confirmed at quote time.

What is the closest functional alternative to 3VA1010-2ED42-0KC0?

The 3VA1010-2ED32-0JA0 is a peer variant in the same 3VA10 frame. The 2ED42-0KC0 carries a shunt trip and 2 HQ auxiliary switches; the 2ED32-0JA0 has a different auxiliary contact configuration. Both share the 100 A TM210 release and 4-pole construction, so they drop into the same mounting footprint without rewiring the power circuit, but the control wiring for the shunt trip and aux contacts differs.

What compliance documentation does Siemens provide for this MCCB?

As a SENTRON series MCCB, it carries CE marking for the European low-voltage directive and is designed to meet IEC 60947-2. UL and CSA listings are standard for the 3VA family; specific certification numbers are printed on the rating label. RoHS and REACH declarations are available from Siemens support.

MPN