Siemens 3VA1010-2ED42-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED42-0KH0 SENTRON MCCB, 100A, 4-Pole, 52.5k

MPN3VA1010-2ED42-0KH0

Siemens SENTRON 3VA1010-2ED42-0KH0, 4-pole molded case circuit breaker, 100 A at 40 °C, breaking capacity 52.5 kA at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1010-2ED42-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10102ED420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1010-2ED42-0KH0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.25 W

Protection & Trip Unit

3VA1010-2ED42-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1010-2ED42-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1010-2ED42-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3

Environmental

3VA1010-2ED42-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1010-2ED42-0KH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

What this MCCB carries and where it fits

The Siemens SENTRON 3VA1010-2ED42-0KH0 is a 4-pole molded case circuit breaker (MCCB) rated for 100 A at 40 °C ambient, with a breaking capacity of 52.5 kA at 240 V AC. It's designed for line protection in distribution panels — the 4-pole configuration covers three-phase plus neutral, common in North American and European commercial/industrial switchboards where a switched neutral is required or local code demands it. Rated insulation voltage is 800 V, so it's comfortable in 480/277 V and 600 V systems with headroom. The 100 A frame at 40 °C holds flat through 50 °C, then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C — useful if the breaker sits in a warm enclosure or near other heat sources. Breaking capacity steps down with voltage: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. That 7.5 kA at 690 V is the figure to check if you're feeding a 690 V drive or transformer primary — it's not a high-fault-duty rating at that voltage, so verify available fault current at the panel.

Auxiliaries and releases — what's built in

This variant ships with a shunt trip (STL) release and an auxiliary switch block: 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). The shunt trip lets you remotely trip the breaker via a control signal — typical for emergency-stop circuits or interlocking with a fire-suppression panel. The HQ block gives status feedback: one set for breaker position (open/closed), one for trip indication. There's no undervoltage release on this order code, and no ground-fault monitoring module. If you need UVR or GF protection, you'd step to a different suffix. The trip indicator flag is present, so a quick visual check at the panel door confirms a trip event. Power loss is listed at 25 W maximum — that's the heat the breaker dissipates at full rated current. Factor it into enclosure thermal calculations if you're packing multiple breakers in a closed panel.

Mounting and dimensions

Dimensions: 130 mm height, 101.6 mm width, 70 mm depth. The 101.6 mm width (4 inches) is standard for a 4-pole MCCB in this frame size — it'll fit existing SENTRON 3VA panel footprints and most DIN-rail or backplate mounting patterns. Depth of 70 mm is shallow enough for compact enclosures.

MPN
3VA1010-2ED42-0KH0