Siemens 3VA1010-3ED32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-3ED32-0AA0-ZD00 Circuit Breaker, 100 A, 25 k

MPN3VA1010-3ED32-0AA0-ZD00

Siemens 3VA1 series, IEC Frame 100, 3-pole circuit breaker, 100 A, switching capacity class N, Icu = 25 kA @ 415 V, TM210 thermal-magnetic trip, lug terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Breaker rating and protection profile

The Siemens 3VA1010-3ED32-0AA0-ZD00 is a 3-pole IEC circuit breaker from the 3VA1 series, Frame 100, with a switching capacity class N rating of Icu = 25 kA at 415 V. That 25 kA interrupting capacity means it can safely clear a bolted fault up to that level without welding contacts or rupturing the case — critical for panel coordination downstream of a transformer or large motor branch. The TM210 thermal-magnetic trip unit is fixed at In = 100 A with non-adjustable overload protection (Ir = 100 A) and a short-circuit pickup Ii = 10 x In, so it holds 1000 A instantaneous. No dials to mis-set; it's a straight swap for any 100 A fixed-trip MCCB application in IEC 60947-2 circuits.

Lifecycle and sourcing

The description notes this variant is built with a lug terminal for DC Power and is OEM-sourced in China. That's a manufacturing origin flag, not a spec limitation — the part carries the same Siemens 3VA1 catalog ratings and approvals as the rest of the family. Sourcing through independent distribution is straightforward; availability and current pricing are confirmed at quote time against an RFQ.

Panel integration notes

The 3VA1 frame mounts on a standard DIN rail or can be screw-fixed to a backplate. The lug terminals accept copper or aluminum conductors sized for 100 A continuous — no compression lugs needed, just a torque wrench. The 3-pole footprint is compact for the 25 kA rating; leave at least 25 mm air gap above and below for arc-quenching clearance per IEC 60947-2 installation rules. No auxiliary contacts or shunt trip are included in this base variant, so if you need remote trip indication or undervoltage release, order those as separate accessories that clip onto the left side of the breaker.

Frequently asked questions

Where can I buy the 3VA1010-3ED32-0AA0-ZD00 and get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of this breaker?

The Icu is 25 kA at 415 V AC, switching capacity class N per IEC 60947-2.

Is the overload protection adjustable on this variant?

No — the TM210 thermal-magnetic trip is fixed at Ir = 100 A overload and Ii = 10 x In (1000 A) short-circuit pickup. No adjustment dials.