Siemens 3VA1010-3ED32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-3ED32-0AD0 SENTRON MCCB, 100 A, 3-Pole, 75.6

MPN3VA1010-3ED32-0AD0

Siemens SENTRON 3VA1010-3ED32-0AD0, molded case circuit breaker, line protection, 3-pole, 100 A, TM210 release, 75.6 kA at 240 V, 70 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1010-3ED32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1010-3ED32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1010-3ED32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1010-3ED32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1010-3ED32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3

Environmental

3VA1010-3ED32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1010-3ED32-0AD0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

SENTRON 3VA1010-3ED32-0AD0 — 100 A MCCB with TM210 Release

The Siemens SENTRON 3VA1010-3ED32-0AD0 is a 3-pole molded case circuit breaker rated for 100 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release. It carries 75.6 kA breaking capacity at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V — the SCCR headroom you need for high-fault panel designs without cascading upstream. Rated insulation voltage is 800 V, and the operating temperature range spans -25 °C to 70 °C. The breaker includes 3 auxiliary switches (HQ type) for status feedback to a PLC or annunciator panel.

Panel Fit & Integration

Dimensions are 70 mm deep, 76.2 mm wide, and 130 mm high — a standard SENTRON 3VA footprint that drops into existing DIN-rail or screw-mounted panel layouts without re-drilling. The IP40 front protection keeps dust out of the enclosure face. The TM210 release is fixed (non-adjustable thermal, fixed magnetic), so selectivity coordination studies should use the published trip curves. No undervoltage release, no shunt trip, no communication module on this variant — it is a straight line-protection breaker.

Frequently asked questions

Where can I buy 3VA1010-3ED32-0AD0 and get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, not listed here.

What is the breaking capacity of this MCCB at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. Use the 415 V figure for most European 400 VAC panels; the 690 V rating covers 600 V class installations.

What compliance documentation does Siemens provide for this breaker?

As a SENTRON series MCCB, it carries IEC 60947-2 certification. RoHS and REACH declarations are available from Siemens support; the reference code per DIN EN 81346-2 is Q.