Siemens 3VA1010-3ED32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-3ED32-0DH0 Circuit Breaker, 100 A, 25 kA @ 4

MPN3VA1010-3ED32-0DH0

Siemens 3VA1 IEC Frame 100, 3-pole circuit breaker, 100 A, switching capacity class N, Icu=25 kA @ 415 V, system protection TM210 with undervoltage release 208-230 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA1 breaker carries

The Siemens 3VA1010-3ED32-0DH0 is a 3-pole IEC circuit breaker in the 3VA1 Frame 100 series, rated 100 A continuous with a switching capacity class N — meaning it interrupts 25 kA at 415 V without upstream fuses needing to clear first. That 25 kA figure is the ultimate short-circuit breaking capacity (Icu), so it handles the full fault current once and stays intact; for repeated faults you'd coordinate downstream devices within the let-through.

Protection and accessories on this variant

System protection TM210 here means a thermal-magnetic trip with fixed overload Ir=100 A (non-adjustable) and short-circuit pickup Ii=10×In. That fixed overload suits it for a dedicated feeder or a motor branch where the load current is known and won't change — no dial to accidentally bump. The built-in undervoltage release (UVR) coils at 208-230 V AC 50/60 Hz; if control voltage drops, the breaker opens, which is standard for emergency-stop or undervoltage protection schemes. Two auxiliary switches (HQ) plus one tripped-signal contact (HQ) give you status feedback back to the PLC or annunciator panel.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA1010-3ED32-0DH0 has an Icu of 25 kA at 415 V AC, switching capacity class N, which is sufficient for most industrial distribution panels with a transformer rating up to around 1600 kVA.

Where can I buy 3VA1010-3ED32-0DH0?

This part is sourced to order through our independent distribution. Submit an RFQ and we will confirm current pricing and availability at quote time.

What does the TM210 designation mean?

TM210 is a thermal-magnetic trip unit with fixed overload protection at Ir=100 A (non-adjustable) and short-circuit pickup set at Ii=10×In (1000 A). The fixed overload suits applications where the load current is stable and won't require field adjustment.

MPN