Skip to main content
Siemens 3VA1010-3ED36-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-3ED36-0BC0 SENTRON MCCB, 100A, 3-Pole, 75.6k

MPN3VA1010-3ED36-0BC0

Siemens SENTRON 3VA1, molded case circuit breaker, 3VA1010-3ED36-0BC0, 3-pole, 100 A at 40 °C, breaking capacity 75.6 kA at 240 V AC, line protection, with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1010-3ED36-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10103ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-3ED36-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.27.5 W
3VA1010-3ED36-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-3ED36-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-3ED36-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1010-3ED36-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-3ED36-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1010-3ED36-0BC0 — 100 A MCCB with undervoltage release

Breaking capacity is specified at five voltage points: 75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V. That spread tells you the interrupting rating collapses above 440 V — at 690 V it is still 7.5 kA, which is adequate for most 690 V distribution but not for high-fault industrial feeders. Selectivity studies should use the 415 V figure for common 400 V systems. Two HQ auxiliary switches are supplied basic.

Frequently asked questions

Does 3VA1010-3ED36-0BC0 include an undervoltage release?

Yes, the design of the auxiliary release is an undervoltage release (UVR). Two HQ auxiliary switches are also supplied as standard.

MPN
3VA1010-3ED36-0BC0